Télécharger Imprimer la page

Tylo CC20 Mode D'emploi page 7

Masquer les pouces Voir aussi pour CC20:

Publicité

Les langues disponibles

Les langues disponibles

Traditional sauna bathing
Dry and wet saunas (70–110°C (158–230°F), 5–30 RH%)
Press ON – only the sauna indicator should be lit. The memory function
automatically sets the previous temperature and humidity.
Press TEMP – if you want to change the pre-set temperature.
Press RH% – if you want to change the humidity setting.
The built-in timer automatically switches the heater off after 3 hours. To
switch the heater off sooner, press OFF. To extend the bathing time, press
ON – only the sauna LED should be lit.
The electronic control logics will not start steam generation until the desired
bathing temperature is reached. Level 1 in the humidity scale = no steam
production.
The electronic control logics will limit the maximum humidity at given
temperatures.
Steam sauna (Tylarium).
(45–70 °C (113–158 °F), 20–65 RH%)
Press ON – until the steam and sauna indicators glow steadily. The memory
function automatically uses the previous settings for temperature and
humidity.
Press TEMP – if you want to change the temperature setting.
Press RH% – if you want to change the humidity setting.
The built-in timer automatically switches the heater off after 3 hours, and the
automatic drying process is activated. The steam and sauna LEDs flash,
even if you manually pressed OFF.
The drying cycle lasts for about 20 minutes, after which the heater switches
off completely. If you do not want to activate the drying process, but prefer to
switch the heater off immediately after bathing, press the OFF button once
more. If you wish to extend the bathing time before the drying process
commences, press ON – the steam and sauna LEDs will glow steadily.
To extend the bathing time after the heater has switched to the drying
process (in other words, when both LEDs are flashing), first press OFF and
then ON. Both LEDs should then shine with a steady light.
Timer settings.
(Unit in OFF position)
The numbers in this case represent the pre-set times (= the number of hours
until the sauna heater automatically switches on). To set the timer:
Press TIME – use the arrow keys to select the desired pre-set time,
1–10 hours.
Press ON – the timer is activated and the time indicator flashes during the
pre-set time period. Once the heater switches on, it remains on for 3 hours,
after which it automatically switches off. If you want to switch it off earlier, just
press OFF. To extend your bathing time, press ON. The LED for the desired
type of bath should be lit.
Main power switch.
At the bottom of the relay box, SE heater and the smaller steam generator
types, there is a main power switch that should only be used if the sauna is
not to be in use for an extended period, such as several weeks. Note: The
memory function must be reset each time the power has been interrupted.
INSTRUCTIONS FOR USE CC 200
13
M o n d a y 1 0 : 0 0 : 0 0
C C 2 0 0 i s o f f
P r e s s O N t o s t a r t
P r e s s I N F O f o r h e l p
TE M P
O N
O F F
1
2
3
Functions.
1 = on, 2 = temperature settings, 3 = off, 4 = lighting, 5 = humidity settings,
6 = move left, 7 = reduce temperature/time/humidity and move down,
8 = move right, 9 = increase temperature/time/humidity and move up,
10 = settings menu, 11 = information menu, 12 = display. 13 = built-in,
factory-set processor, can be customised as needed.
All manuals and user guides at all-guides.com
12
11
INFO
9
MENU
8
R H %
LIG H T
6
7
4
5
A simplified version of these instructions can be found in the
information menu (INFO) on CC 200.
CC 200 has a built-in power reserve and you can choose between
7 different languages.
After each power failure, the model type of the control panel is
displayed for five seconds.
Illumination.
The illumination automatically switches on when the unit starts and switches
off automatically when the unit shuts down. You can also switch the
illumination on or off manually by pressing LIGHT.
Code lock.
Prevents unauthorised alteration of the settings.
Main power switch.
There is a main power switch on the bottom of the relay box, SE heater and
the smaller steam generators. You need only use this switch if the unit is to
be switched off for an extended period.
Hint: Place the thermometer in the Tylarium at such a height that the
measured temperature corresponds exactly to the numbers displayed on the
CC 200.
Stand-by.
Stand-by is invaluable for Tylaria in hotels, public baths, etc. where the
frequency of use varies. During low-frequency periods, the unit is set on
energy-saving "stand-by", which can quickly accelerate to the desired bathing
temperature when you press ON. The stand-by function saves significant
amounts of money each year.
The examples below show how easy it is to programme a suitable bath
schedule.
Stand-by example:
Three different bath facilities are open between 8
bathing frequencies of the facilities varies like this:
Alt. 1) A small number of bathers come sporadically throughout the day.
00
Programme stand-by between 8
attendant) activate the programme by pressing the ON button on the CC
panel, or by pressing on the separate, external ON/OFF switch, if there is
one.
Alt. 2) A small number of bathers come sporadically between 8
00
pm. After 2
pm, there is a steady flow of guests until closing. Programme
00
00
stand-by between 8
am and 8
pm and programme a fixed "ON" time
00
00
between 2
pm and 8
pm. The sporadic bathers activate the programme
by pressing the ON button on the CC panel, or by pressing on the separate,
external ON/OFF switch.
Alt. 3) A large number of bathers between 8
00
00
00
2
pm and 6
pm and 8
pm. The rest of the day, only sporadic bathers
come. Programme stand-by between 8
"ON" times for the steady bathing hours. The sporadic bathers activate the
programme by pressing the ON button on the CC panel, or by pressing on
the separate, external ON/OFF switch.
SETTINGS
all CC 200
Note: Program all settings in the OFF position.
Language.
Press MENU – Use the left and right arrow keys (
language. Start programming mode by pressing the down arrow (
Õ Ö
Use the left and right arrow keys (
×
arrow (
) to exit and press MENU to change language.
Time (clock).
Press MENU – Use the left and right arrow keys (
settings. Start programming mode by pressing the down arrow (
× Ø
Use the up and down arrow keys (
setting by pressing the right arrow (
× Ø
arrows (
), and shift to minutes with the right arrow (
minutes using the up and down arrows (
Press MENU to exit.
00
00
am and 8
pm. The
00
am and 8
pm. The bathers (or bath
00
am and 2
00
00
00
am and 10
am, 1
pm and
00
00
am and 8
pm, programme fixed
Õ Ö
) to move to choice of
Ø
).
) to select the language. Press the up
Õ Ö
) to move to clock
Ø
).
)to set the day. Move to the time
Ö
). Set the hour using the up and down
Ö
). Change the
× Ø
).
00
7

Publicité

loading

Ce manuel est également adapté pour:

Cc200