EngLIsh
5. To reset the telescope press the adjustment for drill bit
length button and extend the telescope out as far as it
will go. Release the adjustment for drill bit length button
and telescope.
Adjusting the Drill Bit Depth (Fig. A)
1. Insert the appropriate drill bit.
2. Retract the telescope 
6
drill bit is protruding past the dust extractor head 
matches the desired hole depth.
3. Press and hold the depth adjustment button 
back along the length of the telepscope as far as it will go.
4. Release the depth adjustment button and the telescope.
The telescope will now not extend past the set depth.
5. To reinstate the maximum drilling depth press and hold the
depth adjustment button and slide it all the way to the end
of the telescope. Release the depth adjustment button.
Emptying the Dust Collection Box (Fig. F, G)

WARNING: Wear approved eye protection and approved
dust mask when performing this procedure.

CAUTION: Do not clean with water or compressed air.
The dust collection box 
 1 
should be emptied as soon as the
performance has noticeably decreased or is full.
1. Press the dust collection box release buttons 
dust collection box away from the dust extraction system.
Once the catch mechanism is clear of the dust extraction
system the upper joint will also release allowing the dust
collection box to be removed completely.
2. To empty the dust collection box 
suitable container to catch the dust contained within it.
Lift up the assembly release latch 
collection box, separating the canister from the filter lid.
Gently tapping the dust collection box will encourage any
dust trapped within the filter to also be removed. Once the
filter lid and canister are empty reattach them, ensuring
the assembly release latch 
Figure G.
3. To reattach the dust collection box to the dust extraction
system first insert the rounded profile of the upper joint
into the recess on the dust extraction system. Pivot the dust
collection box down so that the release buttons click back
into place. Refer to Figure F.
4. With the dust collection box properly installed, depress
the filter cleaning mechanism 
the tool. Allow the system to run for 5 seconds and release
trigger. This should be done after every emptying of the
dust collection box.
MAINTENANCE
Your D
WALT power tool has been designed to operate
e
over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regular cleaning. Empty the dust extractor periodically
or when the performance has noticeably decreased.
18
so that the required length of
10
4
and slide it
 2 
and pull the
 1 
position it over a
to open the dust
 15 
is securely fastened. Refer to
 15 
and pull the trigger on
3

WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect tool from power
source before making any adjustments or removing/
installing attachments or accessories. Be sure the
trigger switch is in the OFF position. An accidental start-up
can cause injury.
Replacing the Dust Collection Box Filter
Assembly (Fig. F)
and

WARNING: Wear approved eye protection and approved
dust mask when performing this procedure.
nOtE: The filter lid (part No. N684523) should be replaced after
every 350 cycles of use.
1. Press the dust collection box release buttons 
dust collection box away from the dust extraction system.
Once the catch mechanism is clear of the dust extraction
system the upper joint will also release allowing the dust
collection box to be removed completely.
2. Discard dust collection box 
3. Reattach the dust collection box to the dust extraction
system. First insert the rounded profile of the upper joint
into the recess on the dust extraction system. Pivot the dust
collection box down so that the release buttons click back
into place.
Lubrication
Your power tool requires no additional lubrication.
Cleaning

WARNING: Electrical shock and mechanical hazard.
Disconnect the electrical appliance from the power source
before cleaning.

WARNING: To ensure safe and efficient operation,
always keep the electrical appliance and the ventilation
slots clean.

WARNING: Never use solvents or other harsh chemicals
for cleaning the non-metallic parts of the tool. These
chemicals may weaken the materials used in these parts.
Use a cloth dampened only with water and mild soap.
Never let any liquid get inside the tool; never immerse any
part of the tool into a liquid.
Ventilation slots can be cleaned using a dry, soft non-metallic
brush and/or a suitable vacuum cleaner. Do not use water or
any cleaning solutions. Wear approved eye protection and an
approved dust mask.
During intensive use the dust collector becomes clogged
with dust. Refer to Replacing The Dust Collector Box Filter
Assembly, under Maintenance.
Optional Accessories

WARNING: Since accessories, other than those offered
by D
WALT, have not been tested with this product, use
e
of such accessories with this tool could be hazardous.
To reduce the risk of injury, only D
accessories should be used with this product.
Consult your dealer for further information on the
appropriate accessories.
 2 
and pull the
replace with a new filter box.
1
WALT recommended
e