Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Ex interfaces
Interfaces
for
analogue
®
signals as well as HART
signals between sensors / I/P
converters / frequency signals and control systems in Ex
zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.
Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Universal
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
All manuals and user guides at all-guides.com
and
digital
5 3 3 4
2 - W i r e P r o g r a m m a b l e
T r a n s m i t t e r
N o . 5 3 3 4 V 1 0 6 - I N ( 0 9 3 4 )
F r o m s e r . n o . 0 6 0 1 6 0 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 13
UK
Page 25
FR
Seite 37
DE

Publicité

loading

Sommaire des Matières pour PR electronics 5334

  • Page 1 All manuals and user guides at all-guides.com Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces analogue digital...
  • Page 2 All manuals and user guides at all-guides.com 2-TRÅDS PROGRAMMERBAR TRANSMITTER PRetop 5334 Indholdsfortegnelse Sikkerhedsinstruktion ............EF-overensstemmelseserklæring ........Anvendelse ................. Teknisk karakteristik ............Montage / installation ............Applikationer ..............Bestillingsskema ..............Elektriske specifikationer............ Tilslutninger ................ Blokdiagram ............... 10 Programmering ..............11 Mekaniske specifikationer ..........
  • Page 3 All manuals and user guides at all-guides.com Sikkerhedsinstruktion EF-OVERENSSTEMMELSESERKLÆRING Ex-installation: Som producent erklærer PR electronics A/S For sikker installation af 5334B i eksplosionsfarligt område skal følgende over- Lerbakken 10 holdes. Installation må kun foretages af kvalificeret personale, der er bekendt DK-8410 Rønde med de nationale og internationale love, direktiver og standarder, der gælder...
  • Page 4 All manuals and user guides at all-guides.com 2-TRÅDS PROGRAMMERBAR TRANSMITTER PRetop 5334 2-trådsinstallation i kontrolrum TC til 4...20 mA • Indgang for TC • Høj målenøjagtighed • Galvanisk isolation • Programmerbar følerfejlsværdi • Kan monteres i DIN form B følerhoved Anvendelse: 2-trådsinstallation...
  • Page 5 All manuals and user guides at all-guides.com Basisværdier Basis Temperatur- Indgangstype nøjagtighed koefficient  ±10 µV  ±1 µV/°C Volt TC-type:  ±1°C  ±0,05°C/°C E, J, K, L, N, T, U TC-type: B, R, S,  ±2°C  ±0,2°C/°C W3, W5, LR EMC-immunitetspåvirkning .........
  • Page 6 All manuals and user guides at all-guides.com Koldt loddestedskomp. (CJC) ..... < ±1,0°C Marinegodkendelse: Følerfejlsdetektering ........Ja Det Norske Veritas, Ships & Offshore ..Standard for Certification No. 2.4 Følerfejlsstrøm: GOST R godkendelse: under detektering ......... Nom. 33 mA VNIIM & VNIIFTRI, Cert. no......Se www.prelectronics.dk ellers .............
  • Page 7 All manuals and user guides at all-guides.com Programmering: • Loop Link er et batteridrevet kommunikationsinterface, der er nødvendigt for programmering af PRetop 5334. • Ved programmering henvises til tegningen nedenfor og hjælpefunktionen i PReset programmet. • Loop Link må ikke benyttes til kommunkation med moduler installeret i Ex- område.
  • Page 8 All manuals and user guides at all-guides.com 2-WIRE PROGRAMMABLE TRANSMITTER PRetop 5334 Contents Safety instructions .............. 14 EC Declaration of Conformity ..........15 Application ................. 16 Technical characteristics ............ 16 Mounting / installation ............16 Applications ................ 17 Order .................. 18 Electrical specifications ............
  • Page 9 Safety instructions EC DECLARATION OF CONFORMITY Ex installation: As manufacturer PR electronics A/S For a safe installation of 5334B in hazardous area the following must be Lerbakken 10 observed. The module must only be installed by qualified personnel who are DK-8410 Rønde...
  • Page 10 All manuals and user guides at all-guides.com 2-WIRE PROGRAMMABLE TRANSMITTER PRetop 5334 2-wire installation in control room TC to 4...20 mA • TC input • High measurement accuracy • Galvanic isolation • Programmable sensor error value • For DIN form B sensor head mounting...
  • Page 11 All manuals and user guides at all-guides.com Basic values Basic Temperature Input type accuracy coefficient  ±10 µV  ±1 µV/°C Volt TC type:  ±1°C  ±0.05°C/°C E, J, K, L, N, T, U TC type: B, R, S, ...
  • Page 12 All manuals and user guides at all-guides.com Cold junction compensation ....... < ±1.0°C Marine approval: Sensor error detection ........ Yes Det Norske Veritas, Ships & Offshore ..Standard for Certification No. 2.4 Sensor error current: GOST R approval: When detecting ........Nom. 33 mA VNIIM &...
  • Page 13 All manuals and user guides at all-guides.com Programming: • Loop Link is a battery-powered communications interface that is needed for programming PRetop 5334. • For programming please refer to the drawing below and the help functions in PReset. • Loop Link is not approved for communication with modules installed in hazard ous (Ex) areas.
  • Page 14 All manuals and user guides at all-guides.com TRANSMETTEUR 2-FILS PROGRAMMABLE (TC) PRetop 5334 Sommaire Consigne de sécurité ............26 Déclaration de conformité CE ..........27 Application ................. 28 Caractéristiques techniques..........28 Montage / installation ............28 Applications ................ 29 Référence ................30 Spécifications électriques ..........
  • Page 15 : Type : 5334 L’année de production ressort des deux premiers chiffres du numéro de série. Nom : Transmetteur 2-fils programmable L’isolation galvanique entre le circuit du capteur et le circuit d’entrée n’est pas...
  • Page 16 All manuals and user guides at all-guides.com TRANSMETTEUR 2-FILS PROGRAMMABLE (TC) PRetop 5334 Installation 2-fils TC en 4...20 mA en salle de contrôle • Entrée TC • Grande précision de mesure • Isolation galvanique • Sécurité programmable • Pour tête de sonde DIN B...
  • Page 17 All manuals and user guides at all-guides.com Valeurs de base Type Précision Coefficient d’entrée de base de température  ±10 µV  ±1 µV/°C Volt Type TC :  ±1°C  ±0,05°C/°C E, J, K, L, N, T, U Type TC : B, R, S, ...
  • Page 18 All manuals and user guides at all-guides.com Compensation de soudure froide ....< ±1,0°C Approbation marine : Détection de rupture sonde ......Oui Det Norske Veritas, Ships & Offshore ..Standard for Certification No. 2.4 Courant de sonde : Approbation GOST R : Pendant la détection ......
  • Page 19 Numéro de référence : Loop Link API ou autres Débranché +Valim. Jaune Rouge Entrée Verte Noir PRetop 5334 Connecteur Loop Link * Connexion facultative Dimensions mécaniques : Montage des fils du capteur Les fils doivent être montés entre les plaques métalliques.
  • Page 20 All manuals and user guides at all-guides.com 2-DRAHT PROGRAMMIERBARER MESSUMFORMER PRetop 5334 Inhaltsverzeichnis Sicherheitsinstruktion ............38 EG-Konformitätserklärung ..........39 Verwendung ................ 40 Technische Merkmale ............40 Montage / Installation ............40 Anwendungen ..............41 Bestellangaben ..............42 Elektrische Daten ............... 42 Anschlüsse .................
  • Page 21 All manuals and user guides at all-guides.com Sicherheitsinstruktion EG-KONFORMITÄTSERKLÄRUNG Ex-Installation: Als Hersteller bescheinigt PR electronics A/S Für sichere Installation von 5334B in explosionsgefährdeter Umgebung muss Lerbakken 10 folgendes beobachtet werden. Die Installation muss nur von qualifizierten DK-8410 Rønde Personen, die mit den nationalen und internationalen Gesetze, Direktiven und Standards des Gebiets bekannt sind, vorgenommen werden.
  • Page 22 All manuals and user guides at all-guides.com 2-DRAHT PROGRAMMIERBARER MESSUMFORMER PRetop 5334 2-Draht-Installation TE en 4...20 mA im Kontrollraum • Eingang für TE • Hohe Messgenauigkeit • Galvanische Trennung • Programmierbare Sensorfehlanzeige • Für Einbau in Anschlusskopf DIN Form B...
  • Page 23 All manuals and user guides at all-guides.com Grundwerte Grund- Temperatur- Eingangsart Genauigkeit koeffizient  ±10 µV  ±1 µV/°C Volt TE-Typ:  ±1°C  ±0,05°C/°C E, J, K, L, N, T, U TE-Typ: B, R, S,  ±2°C  ±0,2°C/°C W3, W5, LR EMV-Immunitätswirkung ........
  • Page 24 All manuals and user guides at all-guides.com Vergleichstellenkompensation (CJC) ..< ±1,0°C Marine-Zulassung: Fühlerfehlererkennung ........ Ja Det Norske Veritas, Ships & Offshore ..Standard for Certification No. 2.4 Fühlerfehlerstrom: GOST R Zulassung: Bei Erkennung ........Nom. 33 mA VNIIM & VNIIFTRI, Cert. no......Siehe www.prelectronics.de Sonst ............
  • Page 25 All manuals and user guides at all-guides.com Programmierung: • Loop Link ist eine batteriegespeiste Schnittstelle zur Programmierung des PRetop 5334. • Bezüglich Programmierung verweisen wir auf die nachfolgende Zeichnung und die “Hilfe”-Funktion im PReset-Programm. • Loop Link darf nicht zur Kommunikation mit Modulen, die in Exgefährdeten Bereichen installiert sind, benutzt werden.
  • Page 26 All manuals and user guides at all-guides.com Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digitale France signalbehandlingsmoduler til industriel automation. Programmet PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, 4, allée des Sorbiers tel.