Télécharger Imprimer la page

BWT EASY DOSE Serie Notice D'installation, D'utilisation Et D'entretien page 37

Publicité

Les langues disponibles

Les langues disponibles

Calibration of the ORP probe
Put the switch to 1 and follow the steps below:
1
H
O
2
5
5 s
Start calibration
9
14.4 BWT Easy Dose ORP Electrolyser
Switch positions:
1 : Normal position to control generation of Chlorine by the electrolyser. The electrolyser generates Chlorine
when both EASY DOSE and the electrolyser are energized, the devices are connected to each other, and
the ORP setpoint has not been reached.
0: EASYDOSE is stopped, the electrolyser does not produce Chlorine.
Selecting the setpoint:
a.
Put the switch to 1
b.
Press the
key until the setpoint value flashes, then press
the desired value is displayed.
c.
Release the
key, 3 seconds later mem will be displayed on screen.
Nota Bene :
- the ORP setpoint can be adjusted between 450 and 980 mV in increments of 10 mV.
- If the measured value is below 400 mV or above 999 mV, the screen will flash.
- The ORP probe measurement range is between 400 and 999 mV.
TRAITEMENT DE L'EAU
2
6
C465
10
Save and return to the
37
3
7
60 s
11
default screen
again to scroll through the setpoint values until
2023/04 - Indice de révision : A - Code : 29600
4
465mV
8
C100

Publicité

loading