B) CLEANING AND LUBRICATION
OF THE WEDGE DISTRIBUTOR BLOCK
To clean up the wedge distributor block in order to avoid any stapling problem,
follow steps 1 to 5 of instructions of A) (ref. page 9), then proceed with step 1 :
1.
Unlock the four corner screws of
the wedge distributor block with the
2.5mm Allen key supplied with the
machine. Separate the two pieces.
3.
After having cleaned up the wedge distributor
block, assemble these both pieces first. Pay
attention to level them on the top before
tightening the screws. The window must be
facing to the both screws' holes.
5.
Before tightening the screws, check the
level of the pieces on the top of the wedge
distributor block in order to have a perfect
reassembly as shown in the picture.
7.
Pull up the crossbar in order to insert the
wedge distributor block on the wedge
driver blade with the window facing the
cartridge channel.
Non contractual document - Cassese France
All manuals and user guides at all-guides.com
9
2.
Unlock the two remaining screws to
remove the center post of the wedge
distributor block. Caution! : These are
the smallest screws of the block.
4.
Insert the last piece as shown in
the picture.
6.
Apply a small amount of
grease at the bottom of the
wedge distributor block.
8.
Tighten the locking screw of the wedge
distributor block, paying attention to
level it with the working table.