CAUTION! To ensure your safety, it is imperative to disconnect the air supply coupler before
any intervention on the mechanical and pneumatic components of the machine.
CAUTION: WHEN USING COMPRESSED AIR, WEAR SAFETY GLASSES.
A) DISMANTLING THE WEDGE DISTRIBUTOR BLOCK
Periodically, remove the wedge distributor block and clean it with an air gun.
It is recommended to lubricate the wedge driver blade (use the Cassese's grease Z1896).
To do so, you will have to remove the wedge distributor block with the 2,5mm Allen Key and
perform this procedure. First, remove the cartridge of wedges from the underpinner.
1.
WEDGE DISTRIBUTOR BLOCK
3.
Pull up the crossbar in order to move
the wedge distributor block out of its
place.
5.
Remove the wedge distributor
block from the machine.
7.
Pull up the crossbar in order to insert the
wedge distributor block on the wedge
driver blade with the window in direction
of the cartridge of wedges.
MAINTENANCE
All manuals and user guides at all-guides.com
Non contractual document - Cassese France
2.
Unlock half a turn the locking screw of the
wedge distribution block with the 2.5mm Allen
key that is supplied with the machine.
4.
Pull
up
distributor block.
6.
Apply a small amount of grease at the
bottom of the wedge distributor block.
8.
Tighten the locking screw of the wedge
distributor block, paying attention to
level it with the working table.