RTD and lin. resistance
TC
2-wire transmitter
mA, VDC or potmeter
28
28
All manuals and user guides at all-guides.com
Output
Type
2 relays
Supply
5116
*NB! Please remember to order CJC connectors
type 5910 / 5910EEx for TC inputs with internal CJC.
Output
Electrical specifications:
2 relays
Specifications range:
Supply
-20°C to +60°C
Common specifications:
Supply voltage, universal ............................ 24...230 VAC ±10%
Internal consumption .................................. ≤ 2 W
Output
Max. consumption ...................................... ≤ 3 W
Fuse ............................................................. 400 mA SB / 250 VAC
2 relays
Isolation voltage, test / operation ............... 3.75 kVAC / 250 VAC
Supply
Communications interface .......................... Loop Link
Signal / noise ratio ...................................... Min. 60 dB (0...100 kHz)
Updating time:
Temperature input .................................... 115 ms
mA / V / mV input .................................... 75 ms
Response time (0...90%, 100...10%), programmable:
Temperature input .................................... 400 ms to 60 s
mA / V / mV input .................................... 250 ms to 60 s
Output
Signal dynamics, input ................................ 22 bit
Signal dynamics, output ............................. 16 bit
2 relays
Calibration temperature .............................. 20...28°C
Supply
Order: 5116
Version
Standard
: A
ATEX Ex approved
: B
50...60 Hz
24...250 VDC ±20%
29
29