3. Set The Regeneration Time Of Day: The default regeneration time is set at 2:00 AM. If you want
to change the time for the regeneration cycle to start follow the steps below.
Step 1. If starting at In-Service display screen press Menu/Confirm key
Step 2. Scroll down to "Advance Settings" in the main menu using the down arrow
Step 3. Press the Menu/Confirm Key
Step 4. Scroll down to "Setting Recharge Time" using the down arrow key
Step 5. Press the Manual/Confirm Key
keys
morning to afternoon. When the correct hour is chosen press Menu/Confirm Key
flashing will advance to the minutes. Use the down and up arrow keys
the correct minutes.
Step 6. Press the Menu/Confirm Key
Step 7. Press the Manual/Return Key
4. Set Capacity (amount of soft water available):
The default capacity is 1306 U.S. Gallons @ 20 grains/U.S. Gallon at medium salt setting.
Step 1. If starting at In-Service menu press Menu/Confirm key
continuing in the main menu scroll down to "Advance Settings" using the arrow keys
Step 2. If already in sub menu scroll down to "Residual Water Setting" using the arrow keys
Press the Menu/Confirm Key
Step 3. Scroll down to "Residual Water" in the sub menu set up using the down arrow key
Step 4. Press the Manual/Confirm Key
Step 5. The capacity residual water volume number will be flashing. Input the water volume capacity
that corresponds to your water hardness. The water hardness was determined by you during
testing of the water that enters your facility. Refer to table on top of the valve under the top
cover or table B below. Use table to determine water volume capacity based on hardness.
Use the down and up arrow keys
Step 6. Press the Manual/Confirm Key
other parameters like salt setting stay in the sub menu. If exiting sub menu proceed to Step 7.
Step 7. Press Manual/Return Key twice
5. Salt Setting At Low, Medium and High:
The water softener default salt settings are at a medium salt setting of 8.0 lbs. of salt for every
regeneration cycle. The option exists for setting the salt setting to low and high salt setting. When the salt
setting is set to low (6.0 lbs. of salt) there will be less soft water available per regeneration cycle.
Therefore you will regenerate more frequently than at medium salt setting. When the salt setting is set at
high (14 lbs. of salt) there will be more soft water per regeneration cycle than low and medium setting.
Low Salt Setting (table A):
Hardness gpg
Soft Water Available
(U.S. Gallons)
Medium Salt Setting (table B):
Hardness gpg
Soft Water Available
(U.S. Gallons)
High Salt Setting (table C):
Hardness gpg
Soft Water Available
(U.S. Gallons)
to scroll to the correct hour. The AM and PM will change as hours advance from
10
15
20
25
2250 1500 1125
900
10
15
20
25
2613 1742 1306 1045
10
15
20
25
2900 1933 1450 1160
to enter the "advance settings" sub menu.
. The hour will start flashing. Use the down and up arrow
will bring you back to "Setting Recharge Time".
twice to bring you back to the In Service Display screen.
to enter the "Advance Settings" sub menu.
to enter the "Residual Water" setting.
to input the volume.
. This will return you to the sub menu. If continuing to set up
to exit the set-up menu to the In-Service Display.
30
35
40
750
643
563
30
35
40
871
747
653
30
35
40
967
829
725
11
to switch to main menu.
.
to switch to the main menu. If
45
50
55
60
500
450
409
375
45
50
55
60
581
523
475
436
45
50
55
60
644
580
527
483
.
and the
to advance to
.
65
70
346
321
65
70
402
373
65
70
446
414

Publicité

Table des Matières
loading

Table des Matières