Madrid 3 Super Madrid 3
English
7) Current used when operating
8) Electrical power used when operating during refrigeration phase (Fans+hot cables+lighting)
9) Electrical power used when operating during defrost phase (Armoured resistances+hot
cables+fans+lighting)
10) Lighting power (where applicable)
11) Net display surface
12) Type of refrigerant fluid with which the system functions
13) Mass of refrigerant gas with which each system has been loaded (only for units with built-in motor)
14) Environmental climatic class and temperature of reference
15) Humidity protection class
16) Unit manufacturing order number
17) Unit production order number
18) Unit year of production
In the case of a request for technical assistance, it is enough to communicate the following for
identification of the unit:
product name (Fig. 2 - 2); serial number (Fig. 2 - 4); work order number (Fig. 2 - 16).
5. TransportationFig. 3)
The cabinets are supplied on a wooden support fixed to the base for movement with forklift trucks.
Always position the forks at the point specified on the wooden support to avoid the risk of
overturning. Use a manual or electrical forklift truck that is suitable to moving the cabinet in question.
It must have a nominal capacity of at least 1,000 kg.
6. Receipt and initial cleaning
Upon acceptance of the cabinet:
- Make sure that the packaging is intact and does not show any obvious damage;
- Unpack, ensuring that the unit is not damaged;
- Check that all parts of the unit are intact;
- If any damage is found, immediately contact your supplier;
- Clean for the first time using neutral products. Dry with a soft cloth. Do not use any abrasive
substances or metal sponges;
- DO NOT use alcohol to clean the methacrylate parts (Plexiglas).
For proper disposal of the packaging, please remember that it consists of: Wood - Polystyrene -
Polythene - PVC - Cardboard.
In accordance with Directive EEC 94/62, we declare the suitability of the above-specified materials.
7. Installation and environmental conditions (Fig. 3)
For installation, please proceed as follows:
- Do not position the cabinet:
- in environments with the presence of explosive gaseous substances;
- outdoors and therefore where there are atmospheric agents;
- near heat sources (direct sunlight,heating systems, incandescent lights, etc.)
- near air currents (near doors, windows, air-conditioning/heating systems, etc.) exceeding speeds of
0.2 m/sec.
- Remove the wooden supports on the bottom (used for transportation) and attach the adjustable feet
(Rif. 2) positioning them so that the unit is horizontal, using a level (Rif. 1) to check the alignment.
- If the unit is moved, repeat the leveling process.
- Before connecting the unit to the power supply, make sure that the rating plate information
corresponds to the characteristics of the electrical system to which it will be connected.
- For correct unit operation, the environmental relative humidity and temperature must be in line with
the parameters specified by standards EN ISO 23953 - 1/2, namely Climatic Class 3 (+25°C; Rel.
Humidity 60%).
Note: All these operations should be performed by specialized technical personnel only.
8. Multiplexing of cabinets (Fig. 6)
MULTIPLEX KIT
Pos. Name
1
Alignment plug Ø 4x80
2
Screws TCEI M8x50 galvanised
16
Code
Ite
02940652
8
04711041
4
05060108 00 16/02/2010