Technical data
Optical data (typ.)
Operating range
Measuring range
Resolution
Light used
Size of light spot
Max. ambient light
Laser protection class
Electrical data (typ.)
Operating voltage U
B
Power consumption I
O
Switching outputs
Output current I
Q
, Q
1
e
Switching frequency (ti/tp 1:1) Q
Response time Q
, Q
1
2
Max. capacitive load Q
Pulse stretching Q
, Q
1
Analogue output Q
A
Serial interface
Linearity
Temperature drift
Repeatability
Protective circuits
VDE protection class
Power-on delay t
v
Mechanical data (typ.)
Casing material
Front screen material
Protection standard
Ambient temperature range
Storage temperature range
Resistance to thermal shocks and vibration EN 60947-2
Connection
Weight
*
smallest, measurable difference
1
*
at ambient temperature: +40 °C
2
*
limit values
3
*
recommended burden ≤ 500 Ohm
4
*
rating 50 V DC
5
*
with attached connector
6
80
FT 80 RLA-500
250 ... 750 mm
500 mm
< 0.1 % of end value of operating range (0.1 mm) *
pulsed laser light, red 650 nm, MTBF > 50.000 h *
see illustr. 4
constant light 5000 lux as per EN 60947-5-2
2 (EN 60825-1)
18 ... 30 V DC *
no load
≤ 40 mA at 24 V DC
Q
≤ 100 mA
2
, Q
≤ 1 kHz
1
2
, Q
≥ 0.4 ms (when averaging = off) / 4 ms / 40 ms to end value
A
, Q
< 100 nF
1
2
50 ms (when activated)
2
4 ... 20 mA *
RS485 (S1 version only)
< 0.25 % of end value of operating range (0.25 mm)
< 0.02 % of end value of operating range / K
< 0.25 % of measuring range
reverse battery protection, short-circuit protection (not RS485)
< 300 ms
PBT
PMMA
IP 67 *
-10 ... +60 °C
-20 ... +80 °C
M12 connector, 8-pin
approx. 107 g
3
/ Q
(PNP, N.O. / N.C. reversible)
1
2
4
*5
6
FT 80 RLA Disctance sensor - GB - 068-13715 - 01.09.2014-05