This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF
Aesthetic Effects
Reduction
Requirements
Chlorine Taste/Odor
50% reduction
Particulate Class I*
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
p-Dichlorobenzene
0.075 mg/L
Carbofuran
0.040 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
Asbestos
>99%
Live Cysts
>99.95%
Turbidity
0.5 NTU
Lindane
0.0002 mg/L
Tetrachloroethylene
0.005 mg/L
O-Dichlorobenzene
0.6 mg/L
Ethylbenzene
0.7 mg/L
Chlorobenzene
0.1 mg/L
Endrin
0.002 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.55 gpm (2.08 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F ± 5°F (20°C ± 3°C).
It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
The disposable water filter should be replaced at least every 6
months.
The filter monitor system measures the amount of water that passes
through the filter and alerts you to replace the filter. When 90% of
the filter's rated life is used, the yellow (Order) light comes on. When
100% of the filter's rated life is used, the red (Replace) light comes on,
and it is recommended that you replace the filter. For models without
filter status lights, replace the filter every 6 months. Use replacement
filter model UKF8001. 2014 suggested retail price of $44.99
U.S.A./$49.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dus
These contaminants are not necessarily in your water supply. Performance may vary based on local water
Fibers greater than 10 um in length
††
‡ Based on the use of Cryptosporidium parvum oocysts
NSF is a registered trademark of NSF International.
®
Interior Water Filtration System
Model UKF8001AXX-200 Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, p-Dichlorobenzene, Carbofuran, Toxaphene, Cysts, Turbidity,
Asbestos, O-Dichlorobenzene, Ethylbenzene, Chlorobenzene, Endrin, Tetrachloroethylene and Lindane.
Average
Influent Challenge
Influent
Concentration
2.00 mg/L
2.0 mg/L ± 10%
14,000,000 #/mL
At least
10,000 particles/mL
Average
Influent Challenge
Influent
Concentration
0.150 mg/L
0.15 mg/L ± 10%
0.150 mg/L
0.15 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.0059 mg/L
0.006 mg/L ± 10%
0.0133 mg/L
0.015 mg/L ± 10%
0.210 mg/L
0.225 mg/L ± 10%
0.0753 mg/L
0.08 mg/L ± 10%
0.015 mg/L
0.015 ± 10%
0.0102 mg/L
0.009 mg/L ± 10%
126.5 MF/L
107 to 108 fibers/L
122,500 #/L
50,000/L min.
10.5 NTU
11 ± 1 NTU
0.0019 mg/L
0.002 ± 10%
0.015 mg/L
0.015 mg/L ± 10%
1.7 mg/L
1.8 mg/L ± 10%
2.2 mg/L
2.1 mg/L ± 10%
2.0 mg/L
2.0 mg/L ± 10%
0.007 mg/L
0.006 mg/L ± 10%
Maximum
Average
Effluent
Effluent
0.06 mg/L
0.050625 mg/L
370,000 #/mL**
196,666 #/mL
Maximum
Average
Effluent
Effluent
< 0.001 mg/L
< 0.001 mg/L
< 0.001 mg/L
< 0.001 mg/L
0.0005 mg/L
0.0003 mg/L
0.0018 mg/L
0.00073 mg/L
0.0005 mg/L
0.0005 mg/L
< 0.0005 mg/L
< 0.0005 mg/L
0.027 mg/L
0.008 mg/L
< 0.001 mg/L
< 0.001 mg/L
0.0027 mg/L
0.00105 mg/L
< 0.17 MF/L
< 0.17 MF/L
††
< 1 #/L
< 1 #/L
0.30 NTU
0.125 NTU
< 0.00016 mg/L
0.000035 mg/L
< 0.0005 mg/L
< 0.0005 mg/L
< 0.5 mg/L
< 0.5 mg/L
0.0048 mg/L
0.11 mg/L
0.0038 mg/L
0.0008 mg/L
0.0004 mg/L
0.0002 mg/L
Refer to the "Water Filtration System" section for the Manufacturer's
name and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
† † †
Minimum%
Average%
Reduction
Reduction
97.00%
97.52%
97.40%
99.00%
Minimum%
Average%
Reduction
Reduction
>99.30%
>99.30%
>99.30%
>99.30%
91.70%
95.00%
69.20%
88.10%
96.10%
96.30%
>99.80%
>99.80%
64.60%
73.45%
>93.3%
>93.3%
76.30%
89.40%
>99.99%
>99.99%
>99.99%
>99.99%
97.30%
98.80%
91.80%
97.90%
>96.6%
>96.6%
>99.9%
>99.9%
99.80%
99.90%
99.80%
99.90%
94.30%
96.80%
City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.55 gpm (2.08 L/min.) @ 60 psi*
conditions.