8
TROUBLESHOOTING THE CONTROL PAN-
EL
Table 1: Sauna temperature sensor failure
Message
Code
Comments
System status
Remedy
Table 2: Electronics in heater overheated
Message
Code
Comments
System status
Remedy
Table 3: Lost contact with control panel
Message
Code
Comments
System status
Remedy
All manuals and user guides at all-guides.com
"Sauna temperature sensor
failure."
0x0001
The thermistor in the sauna
has short-circuited or is not
connected.
The sauna session in progress
will be terminated. A new ses-
sion cannot be started.
Check cables and connections.
Try a new thermistor.
"Electronics in heater over-
heated "
0x0003
Temperature in control box cir-
cuit board higher than 70 °C.
The sauna session in progress
will be terminated. New sauna
session cannot start until the
temperature is below 70 °C.
Wait until the temperature is
below 70 °C.
" Lost contact with control pan-
el."
0x0006
The system has restarted be-
cause the control box could not
communicate with one of the
control panels.
The control box will restart
after 60 seconds when con-
nection to the control panel is
lost.
Restarting the system. Check
cables and connections. Re-
place control panel.
Table 4: Lost contact with temperature/humidity sensor
Message
Code
Comments
System status
Remedy
Table 5: Hardware error. Contact service.
Message
Code
Comments
System status
Remedy
Table 6: Power outage. Set time.
Message
Code
Comments
System status
Remedy
Table 7: Firmware panic 0x%02x!
Message
Code
Comments
System status
Remedy
"Lost contact with temperature/
humidity sensor."
0x0007
The system has restarted be-
cause the control box could not
communicate with one of the
sensors.
The control box will restart
after 60 seconds when con-
nection to the control panel is
lost.
Restarting the system. Check
cables and connections. Re-
place sensor.
"Hardware error. Contact ser-
vice."
0x0009
Realtime timer not working.
Timer time and date not up-
dated.
Restarting the system. If same
error recurs, the circuit board
in the control box may need re-
placing.
"Power outage. Set time."
0x000a
Realtime timer reset.
Time and date set to default.
Enter current time and date.
"Firmware panic 0x%02x!"
0x0010
An error has occurred in the
software.
The system will restart when
the error has been corrected.
Restarting the system. If the
error recurs, contact Service.

Publicité