STEP 5 - TESTING AND GETTING TO KNOW YOUR MONITOR
The Angelcare
®
monitor can be used with the pre-program factory settings
or you can also customize your settings to your preference.
5.1 - SENSOR PAD
TO ACTIVATE THE SENSOR PAD:
1
TO TEST THE SENSOR PAD:
1
MOVEMENT ALARM
• Alarm activates when no movement is detected by Sensor Pad for 20 seconds.
• Both the Parent Unit and Nursery Unit speakers will emit loud warning sound.
• Movement Alarm icon will show on the LCD screen.
IF THE ALARM DOES NOT SOUND
• Avoid contact with crib while Sensor Pad is in operation. If the child's room
has a wooden floor, then leave the room for a moment.
• Place crib near a supporting wall.
• Adjust the Sensor Pad sensitivity level.
98
All manuals and user guides at all-guides.com
NOTE: All changes
and adjustments made
in the settings mode will
not be activated unless
you confirm them by
pressing the Return icon.
A long beep will confirm
your modification.
2
IMPORTANT
When in setting mode, sound
transmission and movement
detection between Parent and
Nursery Unit will be temporarily
deactivated. ONLY the movement
alarm will remain active
(if function is activated).
1) Press Sensor Pad icon to activate
or deactivate movement mode.
ON
When the movement mode is OFF
the 'TIC' mode is automatically set OFF.
This allows you to detect the baby's
sounds ONLY.
1) Move your hand lightly on the mattress.
2) Remove your hand from the mattress.
After 15 seconds you will hear a
'TIC' pre-alarm sound, and 5 seconds
later the Movement Alarm will trigger.
3) Repeat by moving your hand lightly
in all four corners of the mattress.
Ensure the Nursery Unit Movement
Indicator is still flashing.
OFF

Publicité