Télécharger Imprimer la page

Güde UNI MIG 125 SYN Traduction Du Mode D'emploi D'origine page 33

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
Technical Data
Welder
Art. No ...............................................................................................................................................................................................20078
Service connection ............................................................................................................................................. 230 V ~ 50 Hz
Rated input voltage (AC Voltage) U
Protection ................................................................................................................................................................................ 16 A
Maximum rated input current I
Maximum eective input current I
Idle voltage U
....................................................................................................................................................................................63 V
0
Degree o protection.................................................................................................................................................................... IP 21S
Insulation class ........................................................................................................................................................................................ H
Dimensions ......................................................................................................................................................... 305 x 152 x 233 mm
Weight ....................................................................................................................................................................................6,4 Kg
..................................................................................MMA ................................MIG/MAG ..........................................WIG
Welding current I
........................................................100 A .............................................120 A .............................................100 A
2
Operating voltage U
.....................................................22 V ................................................20 V ................................................14 V
2
Material thickness ................................................ 1.08 mm .................................... 1,0 8 mm .................................... 1,0 8 mm
Regulated section ..................................... 20  100A ..................................... 20  120A ....................................... 20100A
Electrodes .................................................1,63,2 mm ..................................0,61,0 mm ..................................1,62,4 mm
* Actual working time and total working time ratio.
Read and understand the operating
instructions beore using the
appliance. Abide by all the saety
measures stated in the service manual. Act responsibly
toward third parties. In case o any doubts about
connection and operation reer please to our customer
center
Specied Conditions Of Use
Welder in protective atmosphere or thermal connec
tion o errous metals by melting edges and including
mixture. Please note that the device is designed or
domestic use only.
Do not use this product in any other way as stated or
normal use. Not observing general regulations in orce
and instructions rom this manual does not make the
manuacturer liable or damages.
Please note that our equipment has not been designed
or commercial, crat or industrial use. I the equipment
is used in commercial, crat or industrial operation or or
similar activities, we cannot assume any
Safety instructions
WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
........................................................................................................................................ 230 V
1
..........................................................................................................................................17,3 A
1max
.....................................................................................................................................12,7 A
1e
Operation is only allowed with a safety
switch against stray current (RCD max. stray
current of 30mA).
IP21 protection degree o the welder. The welder
must not be exposed to rain and moisture when
being operated or stored.
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Insert the plug o the electrical cable in a socket o
suitable shape, voltage and requency complying
with current regulations.
Use extension cables with a maximum length o 5
meters and with a cable crosssection o not less than
1.5 mm2. Use o extension cables o dierent length
and crosssection and also o adapters and multiple
sockets should be avoided.
Check the cable and/or socket or damages beore the
appliance putting into operation.
Deective cable or plug may cause electric shock.
Do not pull the service cable to pull the plug out o
socket. Do not expose yoursel or other persons wit
hout protection to electric arc or hot metal. Spraying
welding pearls may cause burns. A suitable welding
shield, protective clothes and protective gloves to be
worn at all times.
ENGLISH
UNI MIG 125 SYN
27

Publicité

loading

Ce manuel est également adapté pour:

20078