ELECTRICAL WIRING
230V
N
1
2
Valve
Black
D5228
NOTES
– Wires of 1,5 mm
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
– To remove the control-box from the burner,
loosen screw (A) (see figure) and pull
towards the arrow.
– The flame sensor is fitted directly into the control-
box (underneath the ignition-transformer) on a
plug-in support.
TESTING
Check the shut-down of the burner by opening
the thermostats.
2094
~
50Hz
L
Main switch
T6A
N
L
3
4
5
6
Black
Capacitor
2
section.
WARNING
Remote lock-out lamp
(230V - 0.5A max.), if required
Terminal block of
7
8
9
control-box 530SE
M
~
Motor
S7029
RUN OF THE ELECTRICAL CABLE
1 - Grommet
2 - Cable-clamp
3 - Terminal block
5
GB
DO NOT EXCHANGE THE
NEUTRAL WITH THE PHASE
Regulating thermostat
T
Limit thermostat
T
with manual resetting
*
N - Neutral
L - Phase
- Burner-earth