vibrationfree, exact vertical and stable enough for lastingly holding the appliance
free of problems. Check or the provided dowels and screws are suitable, strong
enough and qualified for the foundation. The material provided is identified for a
brick wall; for another foundation please ask the specialist for suitable material.
Check before mounting or the minimum safe mounting distances between heater
and environment are strictly followed. The distance between the bottom edge of
the appliance and the floor must be at least 1,8 meter. There must be a distance
of at least 0,3 meter between the appliance and the ceiling, roof or other cover.
If the covers consist of flammable material
(p.e.
wood,
distance has to be at least 1 meter and if
you focus the radiator upwards, at least 2
meter. There must be a distance of at least
0,5
meter
at
appliance and walls or the like. When you
install the appliance outside, pay attention
that it doesn't catch excessive wind load.
Fix the mounting bracket totally horizontal
on the wall with the three anchor dowels
provided. The short side of the bracket has
to point upwards (see fig.).
Assemble the appliance onto the mounting
bracket with the two winged nuts, the cable
at the underside of the appliance (see fig.).
Adjust the desired angle of radiation. The
radiator can turn 115°: from half upside till
almost totally downwards. Pay attention that
the radiator doesn't focus its heat from a
short distance at combustable materials!
The recommended number of degrees to the
mounting wall is 45 ° (see fig.)
Fasten all screws another time firmly and
scheck or the heater is firmly mounted. Now
your infra red heater is ready for use.
For personal protection the installation, to which the Eurom Golden Comfort is
connected, has to be equipped with an earth fall device (max. 30 mAmp).
Under some circumstances it may be attractive to make a fast connection between
the heater and the main supply, and to operate the heater with a switch. Because
the Eurom Golden Comfort has a high water tightness (IP65) and for safety
reasons, such a connection has to be made by a qualified electrician.
Working
Check for every use:
- or the appliance doesn't show signs of damage.