Télécharger Imprimer la page

Ferroli ELDA Instructions Pour L'installation Et L'entretien page 200

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Submenu MN02 – 4 weekend prog
Used to enable/disable and set the chronothermostat functions on the weekend (days 6 and 7, Saturday and
Sunday).
To enable, press the ON/OFF button in the item "weekend chrono" and set "on" using the – button (decrease) or
the + button (increase).
▪ To set the operating period for SATURDAY, set the times Start 1 weekend and Stop 1 weekend.
▪ To set the operating period for SUNDAY, set the times Start 2 weekend and Stop 2 weekend.
Menu level
MN02-4-01
WEEKEND CHRONO
MN02-4-02
STAR 1 WEEKEND
MN02-4-03
STAR 1 WEEKEND
MN02-4-04
STAR 2 WEEKEND
MN02-4-05
STAR 2 WEEKEND
6.2.3. MENU MN03 – LANGUAGE SELECTION
For selecting the desired language. To move to the next language, press the + button (increase) and to return to the
previous one, press the – button (decrease). To confirm, press ON/OFF.
6.2.4. MENU MN04 – STANDBY FUNCTION
For enabling or disabling the standby mode. Once menu M4 has been selected with the ON/OFF button, press the
– button (decrease) or the + button (increase) to change the status from ON to OFF and vice versa. For operation,
refer to par. "Standby" 7.8
6.2.5. MENU MN05 – SOUND
For enabling or disabling the board buzzer during alarm signaling. To enable or disable, press the – or + buttons,
and to confirm, press ON/OFF.
6.2.6. MENU MN06 – MANUAL LOADING
The manual loading function can be activated only when the board is OFF, it allows auger loading for a specified
time. After selecting Menu M6, the message "Press plus" scrolls on the display: press the + button (increase). The
fume fan turns on at maximum speed, the auger turns on (auger LED on) and they stay on until the time shown on
the display ends, or until the ON/OFF button is pressed.
6.2.7. MENU MN07 – STOVE DATA
On accessing the M7 menu, after pressing the ON/OFF button, some variables scroll on the display when the unit
is working. The table gives examples of the display of some set parameters.
Status displayed
3.1sec
52min
Toff
106°
1490
200
WEEKEND PROGRAM
Selection
Meaning
Pellet feed auger status
Current phase cycle time
External thermostat status
Fume temperature
Fume extraction speed RPM
A73023860 - Rev 01 - 06/2023
Meaning
Enable weekend chrono
Activation time
Deactivation time
Activation time
Deactivation time
ELDA - CORONA
Possible values
ON/OFF
OFF-0-23:50
OFF-0-23:50
OFF-0-23:50
OFF-0-23:50
EN