Télécharger Imprimer la page

Ferroli ELDA Instructions Pour L'installation Et L'entretien page 191

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ELDA - CORONA
5.5.3. ELECTRICAL CONNECTION
Make sure the electrical system is compliant, and provided with grounding and
differential switch in accordance with the applicable Standards. Unsuitable
grounding of the system can cause a malfunction for which the Manufacturer is not
liable.
The unit is equipped with a power supply cable fitted with a Shouko plug. Connect the unit to an approved 230V - 50
Hz electrical outlet. The power outlet must be easily accessible even after installing the unit.
When the unit is not being used, it is advisable to unplug the power cable.
If the power cable is damaged, it must be replaced immediately by the after-sales service or by a
qualified technician in order to prevent any risk.
The power cable must never touch the unit's exhaust pipe. The fume exhaust duct
must have its own ground connection.
con elettronica DUEPI Group e produzione Spagna
The supply voltage must match that given on the unit's dataplate and in the
technical data section of this manual. Power supply variations greater than 10%
can cause unit malfunctions.
5.5.3.1.
WIRING DIAGRAM
Legend
A1 Fume fan
A2 Auger motor
A6 Heating element
A14 Air fans
B3 Fume probe
B4 Room thermostat (opt.)
EN
SCHEMA ELETTRICO
A73023860 - Rev 01 - 06/2023
B12 Fume encoder
B13 Flow meter (not present)
B14 Pressure switch
B15 Pellet safety thermostat
B17 Room probe
B18 Pellet door opening microswitch safety
(present on hermetic vers.)
191

Publicité

loading

Ce manuel est également adapté pour:

Corona