Télécharger Imprimer la page

Chamberlain Whisper Drive Security+ WD962KCD Manuel D'instructions page 17

Masquer les pouces Voir aussi pour Whisper Drive Security+ WD962KCD:

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum
height of 5 feet (1.5 m) where small children cannot reach,
away from moving parts of door and door hardware.
If installing into drywall, drill 5/32" holes and use the
anchors provided (Figure 1). For pre-wired installations (as
in new home construction), it may be mounted to a single
gang box (Figure 2).
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back of
the door control by color: white wire to 2 and white/red
wire to the 1.
2. Remove cover by gently prying at slot in top of the
cover with a small fl at head screwdriver. Fasten with
6ABx1" self-tapping screws (drywall installation) or
6-32x1" machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
• Position bottom of the door control on screw head
and slide down to secure. Adjust screw for snug fi t.
• Drill and install top screw with care to avoid cracking
plastic housing. DO NOT overtighten.
• Insert top tabs and snap on cover.
3. (For standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated staples
to secure wire in several places. DO NOT pierce wire
with a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety reverse test label in a prominent location
on inside of garage door.
NOTE: DO NOT connect power and operate opener at
this time. The trolley will travel to the full open position but
will not return to the close position until the sensor beam
is connected and properly aligned.
Bell
Wire
(BACK VIEW)
Top
Mounting
Door Control Connections
Hole
Terminal
Strip wire 7/16" (11 mm)
Screws
Bottom
Mounting
Hole
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Disconnect ALL electric and battery power BEFORE
performing ANY service or maintenance.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from
a closing garage door:
• Install the door control within sight of garage door,
out of reach of children at a minimum height of
5 feet (1.5 m), and away from ALL moving parts of
door.
• NEVER permit children to operate or play with the
door control push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to
door travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of
closing garage door.
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white;
white/red to red.
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1"
(Standard installation)
Screw 6-32x1" (Gang box installation)
Figure 1
STANDARD WALL MOUNT
To Replace
Insert Top
Tabs First
Push Bar
Detector
Cover
Switch
To insert or release wire, push
in tab with screwdriver tip
Red White Grey
17
Insulated Staples
(Not shown)
Drywall Anchors
Figure 2
PRE-WIRED INSTALLATION
24 Volt
To Replace
Bell Wire
Insert Top
Tabs First
ON
OFF
Push Bar
Detector
Cover
Switch
ON
OFF

Publicité

loading