3.0 Facing and Finishing
See below for some fireplace specific finishing material information:
Bellingham 38
The Bellingham 38 are equipped only with a safety screen that fits inside the finishing edge. Finishing material, mantel pro-
jections, and hearth projections may butt up against the finishing edge.
•
If you are purchasing the optional rectangle surround (Part #BH38-RS) finishing material up to 1-1/4" in total thickness
can continue to be finished up to the fireplace finishing edge and the optional surround can be installed over the top of
the finishing material. These optional surrounds have a slotted bracket to secure the surround to the fireplace that al-
low this installation over up to 1-1/4" thick finishing material.
•
If you have combined thickness of finishing material over 1-1/4" we recommend butting the finishing material up
against the finishing edge and not using the optional surround.
•
The optional surround must be able to be removed for service work. Ensure the finishing material does not inhibit this.
Nordik 41 DV
The Nordik 41 DV is supplied with a "Finishing Trim Kit". It is highly recommended that this kit is installed and used with the
fireplace. The finishing trim kit provides a finishing edge for material to butt up against while providing the necessary clear-
ance for the safety screen barrier to be removed.
IMPORTANT: The B41-PSF2 and B41-FRSF2 (Figure 3.1) are ONLY approved for use when the Nordik 41 DV is installed with
the #KZK-038. The other (4) safety barriers shown in Figure 3.2 are approved in all installation scenarios.
Safety Barriers Approved for All Design Options
(Standard or Kozy Zone Kit Installations)
Figure 3.1 - Safety Barriers Group #1
KZK Plenum
Section 3.2 will provide information about finishing material around the KZK plenum.
KZK-038
Safety Barriers Approved for
Kozy Zone Kit Installations ONLY
Figure 3.2 - Safety Barriers Group #2
12
Rev. 2 — May 2023