IMPORTANT
The owner of the Mobile Home
undertakes to assume all
responsibility in this regard,
to have it reviewed annually
or whenever required by law
standards, the entire gas system
using qualified technicians. This
warning also applies if the Mobile
Home is rented or sub-rented.
It is strictly forbidden to make any
changes to the gas system.
In any case, any intervention
must be carried out exclusively by
68
an expert and qualified technician.
Any transformation from natural gas
to LPG gas and vice versa must be
carried out exclusively by qualified
technical personnel.
When the gas-powered internal
devices are not used (e.g. the hob) it
is advisable to close the gas supply
by acting on the internal closing
valve.
Periodically inspect the gas hoses
and replace them with an approved
type when necessary and in any
case no later than the expiry date
indicated on the hose - obviously
this operation must be carried out
by qualified technical personnel.
M O B I L E
H O M E
ATTENTION IF YOU
SUSPECT A LOSS
1. Immediately close the main
power supply located outside under
the floor immediately near the
label "GAS STOP VALVE" indicated
underneath.
2. Never attempt to detect a leak
using an open flame!
3. CONTACT IMMEDIATELY
an authorized person or, if you
are in warranty, contact directly
the Service Crippa Campeggio:
service@crippacampeggio.it
TEL: +39 345 7567366
aftersales@crippacampeggio.it
ATTENTION
Never seal the perimeter of the
Mobile Home as it is necessary
that the lower part of the floor is
ventilated!!!
This is necessary both to maintain
its structural integrity for a
long time, and for your safety
and security, as this ventilation
is necessary to dispose of any
accidental leaks of unburned gas.
M A I N T E N A N C E
A N D
U S E
M A N U A L
E L E C T R I C W AT E R
H E AT E R S
The electric water heater is installed
inside the technical compartment
accessible only from outside the
Mobile Home.
The water heater used is a common
domestic water heater.
For the technical characteristics,
please refer to the use/maintenance
manual provided by the
manufacturer of the water heater
itself.
During the winter the water heater
must be emptied using the depleted
system shown (Image 3, page 70).
DRAINAGE PROCEDURE
a. Turn off the power supply to the
boiler.
b. Close the main water supply.
c. Make sure the water temperature
is below 40° C.
d. Remove the caps for emptying.
e. Open the valve for emptying.
f. Wait until all the water flows out.
g. Once the boiler has been emptied,
you can proceed to complete
emptying of the water system using
a hose with compressed air.
h. Open all the taps in the house.
i. Then introduce air into the water
supply system until the system is
completely discharged - we also
recommend placing antifreeze in the
toilet bowl to avoid freezing of the
water left in the goose-neck of the
same.
ATTENTION
In the case of temperatures
below 0 ° C the water heater must
be filled only if the appliance
is electrically powered and
switched on (on) if these are not
implemented conditions the water
will freeze in and damage the
appliance irreversibly.
MOBILE HOME EQUIPPED WITH
ANTI-FREEZE HYDRAULIC PIPE
SYSTEM WITH CABLE HEATING
If the Mobile Home is equipped
with an antifreeze system for the
pipes, you will find specific warning
signs inside the technical room and
inside the door of the electrical
switchboard, in this case it is
necessary to follow the following
operating instructions.
› Use during the winter period and
whenever the outside temperature
can cause frost.
› Activate the system by turning
the "HEATING CABLE" electrical
switch on the Mobile Home
electrical panel to ON.