US
9
OPERATION
General safety regulations for the handling of the equipment can be found on
page 17. Read through before you start using the equipment!
9.1
Connections and control devices
1
Connection for welding current cable (+)
(SMAW welding)
2
Connection for remote control
3
Connection for return cable (-)
4
Main power supply switch, 0 / 1 / START
5
White indicating lamp - Power supply ON
9.2
Turning on the power source
Turn on the mains power by turning switch (7) to the "START" position. Release the
switch, and it will return to the "1" position.
If the mains power supply should be interrupted while welding is in progress, and
then be restored, the power source will remain de-energised until the switch is again
turned manually to the "START" position.
Turn the unit off by turning the switch to the "0" position.
In the event of a loss of suppply power or of turning the power source off in the
normal manner, welding data will be stored so that it is available next time the unit is
started.
ba38d1aa
6
Orange indicating lamp - Overheating
7
Connection for welding current to the wire
feed unit
8
Connection for control cable to the wire
feed unit or for the terminating resistor
9
Fuse for supply voltage for feeder unit, 42
V
- 22 -
© ESAB AB 2003