Recommended fuse sizes and minimum cable areas
Mig 5000i
Mains voltage
Mains cable area, CU/AWG (mm
Phase current, I RMS
Fuse Time Delay
NB!
Sizes per National Electric Code for 90° C rated cooper conductors @30° C ambient. Not more
than three conductors in raceway or cable. Local codes should be followed if they specify larger sizes
other than those listed above.
8.4
Terminating resistor
In order to avoid communication interference, the ends
of the CAN bus must be fitted with terminating
resistors.
One end of the CAN bus is at the control panel, which
has an integral terminating resistor. The other end at
the power source must be fitted with the terminating
resistor, as shown on the right.
ba38d1aa
Check that the unit is connected to the correct mains power
supply voltage, and that it is protected by the correct fuse sizes.
A protective earth connection must be made, in accordance
with regulations.
Rating plate with supply connection data
2)
- 21 -
460 V 3 60 Hz
460 V
4G6
28 A
50 A