Before commissioning, fill the wet cup halfway with lubricant "T".
The wetting cup nut must be tightened moderately. Overtightening
quickly damages the gland packing. A wrench is supplied to allow
proper tightening.
 Verify cup is filled with lubricant T,
 Run the pump, then tighten the cup after 10 minutes, again
after 1 hour, then after1 day of operation,
 In the event of a leak, the cup must be tightened.
 Depressurize the Air motor (see depressurization procedure),
 Depressure
procedure),
 Tighten the cup, clean it and fill it with lubricant T,
 Close the pump purge circuits,
 Open the Air motor air valve.