3 Environment
582131110-2B0225-indA-EN.docx
The equipment must be installed on a horizontal, stable and flat
ground (eg concrete slab).
Non-moving equipment must be fixed to the ground by suitable
fasteners (spit, screws, bolts, ...) to ensure their stability during use.
To avoid risks due to static electricity, the equipment and its
components must be grounded.
 In combination with a pneumatic motor, the hydraulics will
be earthed via the earth cable of this motor. This earth cable
must be connected to a safe earth.
 Have
the
earth
electrician. If earth continuity is not assured, check terminal,
wire and grounding point. Never operate the equipment
without solving this problem.
 Do not store more flammable products than necessary
inside the work area.
 These products must be stored in approved containers and
grounded.
 Use only grounded metal buckets for the use of rinse
solvents.
 Cartons and papers are to be banned. Indeed they are very
bad conductors, even insulators.
continuity
checked
by
27/10/2020
Environment
a
qualified
15

Publicité

loading

Ce manuel est également adapté pour:

146310000