Step 2. Use the template to mark-out and prepare the mounting area
Method 1: To flush mount using screws
1. Create a circular opening in the mounting surface with
a diameter of 120 mm (4.7") with tolerances of -0/+5 mm (-
0/.0.2").
2. Create three 6 mm (0.2") holes at the T3 template
positions. Then insert the screw anchors into the holes.
Notes:
-
Not intended for drop ceiling installation without
appropriate lanyard.
-
Not intended for installation in ceilings used for
environmental air return.
Method 2: To surface mount
1. According to your needs, create 6 mm (0.2") holes at the T1/T2 template positions. Then insert the
screw anchors into the holes.
2. If you want to feed wiring from the hole on the top of the back case, create a circular opening (bottom
conduit hole) in the mounting surface.
Method 3: To surface mount using junction box
No need to mark-out and prepare the mounting areas. Skip to next section for mounting instructions.
All manuals and user guides at all-guides.com
1. Camera Installation
3