7.4 Charger Installation Requirements
To select the best location and position to
install the wall-mount unit, you should first
determine the parking position of the
vehicle to ensure the charging connector
can be easily inserted into the vehicle
charging inlet. The wall-mount unit should be
located:
In a well-ventilated area. Avoid
installing in closed boxes or near the
exothermic chargers.
1.2 meters or 4 feet above the floor.
250mm (10inches) from any obstacles
to allow cables to loop around the
wires and related maintenance.
If in an enclosed garage, on the side
of vehicle charging inlet.
7.5 Installation Steps
Warning for Wi-Fi and 4G versions: Due to
different congenital environments, it is
recommended to first conduct Wi-Fi and 4G
module network signal tests before finalizing
your settings. It is recommended that the
RSSI (Received Signal Strength Indication)
value should be higher than-65dBm. If it is
lower than this value, it may result in a weak
Wi-Fi or 4G connection or disconnection due
to external interference in the area.
Step 1
Use screwdriver to loosen the 9 fixed screws
on the rear of charger, then remove the
front cover.
Step 2
Connect and lock the M25 waterproof
gland Part1 and Part2 (including the
washer) to the mounting holes as shown
below.