PEV-AW32 User Manual
Power Grid Connection and Grounding
Type
This AC charger supports different
power
grid
grounding types. You can configure
through the setting dip switch. Setting
methods are shown below.
Before setting the dip switch, make
sure the input power is turned OFF.
Use a non-conductive object to set
the dip switch.
Switch 1
(Power Grid Type)
ON
LN
OFF
LL
* Note 1: The default value in North America and
Japan is (LL / TT-TN).
* Note 2: The default value for other regions is (LN
/ TT-TN).
* Note 3: If it is not the above standard grid type,
please contact our technical staff for assistance
and confirmation.
connections
and
Switch 2
(Grounding System)
IT
TT-TN
Maximum Output Current
This AC charger can support different
maximum output current through the setting
rotary switch. Setting methods are shown
below:
Before setting the rotary switch, make
sure the input power is turned OFF.
Use a non-conductive object to set
the rotary switch.
* Note 4: The default value for Japan is 30A.
* Note 5: The default value in other countries is
32A.