PEV-AW32 User Manual
Power Grid Connection and Grounding
Type
•
This AC charger supports different
power
grid
grounding types. You can configure
through the setting dip switch. Setting
methods are shown below.
•
Before setting the dip switch, make
sure the input power is turned OFF.
•
Use a non-conductive object to set
the dip switch.
Switch 1
(Power Grid Type)
ON
LN
OFF
LL
* Note 1: The default value in North America and
Japan is (LL / TT-TN).
* Note 2: The default value for other regions is (LN
/ TT-TN).
* Note 3: If it is not the above standard grid type,
please contact our technical staff for assistance
and confirmation.
connections
and
Switch 2
(Grounding System)
IT
TT-TN
Maximum Output Current
This AC charger can support different
maximum output current through the setting
rotary switch. Setting methods are shown
below:
•
Before setting the rotary switch, make
sure the input power is turned OFF.
•
Use a non-conductive object to set
the rotary switch.
* Note 4: The default value for Japan is 30A.
* Note 5: The default value in other countries is
32A.
7