Main parameters:
WHB COMBY
Minimum running costs
par. 1.13.3 Gas kWh cost (GCV)
Gas tariff (cent/kWh)
par. 1.13.4 Electricity kWh cost
Electricity tariff (cent/kWh)
par. 1.13.5 Electricity kWh cost (low tariff )
Reduced electricity tariff (cent/kWh)
38 / EN
par. 2.2.7 Boiler Hybrid
Set to 2 --> Enabled
HYDRAULIC SCHEME AND RELATED PARAMETER SETTING
1.0.2 - Tank Management
0 - None
ENERGY MANAGER LOGIC AND RELATED PARAMETERS
par. 1.0.5: Energy Manager Logic
BOILER SETTINGS
par. 2.2.8 Boiler version
set 2 --> Storage with Thermostat
par. 1.9.0 DHW Comfort Setpoint T
set sanitary comfort temperature
par. 1.9.1 DHW Reduced Set Point T
set sanitary reduced temperature
par. 1.9.2 Comfort Function
Disabled / Time based / Always Active
par. 1.9.4 Tank charge mode
- standard (heat generator defined by the Energy
manager logic, par. 1.0.5)
- Only HP (heat pump)
- Fast (boiler and heat pump activated)
par. 1.9.6 Thermal Cleance Function
OFF - ON (deactivated - activated)
Max efficiency
par. 1.13.2 Primary/Elec Energy Ratio (Valx100)
iset value defined by the National authority
WHB SYSTEM (TANK)
1 - Tank with NTC