TEST THE EQUIPMENT
Check the pressure of the incoming gas line
Before supplying gas to the regulator, check the pressure of the
incoming gas line.
The regulator can withstand a maximum pressure of 14" WC (1/2 PSI).
If the line pressure is beyond this limit, a step-down regulator will be
required. The arrow on the regulator body shows gas flow direction and
should point toward the appliance.
Check for gas leaks
NOTICE: Matches, candle flame, or any other potential source of
ignition shall not be used for this purpose.
1. Turn the knob for the main burner(s) to the OFF position.
2. Remove the main burner control knob(s).
3. Use a flathead screwdriver to remove the screws on the front panel.
Remove the front panel to access the pilot burner control valve(s).
4. Locate the pilot burner control valves for the pilot lights and turn
them OFF by turning the small forward-facing screw clockwise until
tight.
5. Connect the equipment to the gas supply.
6. Apply soapy water to each connection.
7. Turn ON the main supply valve.
8. Look for bubbles at the connections.
9. Adjust the connections as needed.
Light the pilot burners
1. Wait 5 minutes to allow any gas to dissipate.
2. To light the pilot burners, hold a flame source over the desired pilot
burner while slowly turning its control valve screw
counterclockwise, adjusting the flame to the desired intensity.
Repeat for all pilot burners.
Test the main burners
After lighting all of the pilot burners, ensure that each main burner
functions correctly.
Reassemble the equipment
Allow the burners and surrounding surfaces to cool before
reassembling the equipment.
®
Cayenne
Medium-Duty Flat Top Griddles – Conversion to LP Gas Installation Instructions
Affix the labels
1. Affix the Rating Plate, supplied in the kit, adjacent to the original on
the rear of the griddle.
The Vollrath Company, LLC
Sheboygan,WIUSA
1-888-882-6845
Griddle, Gas, Flat Top, MD, 24"
Item: 40 20
Converted for use with LP (propane) Gas
Model: FTG9024
Orifice Size: #53 Drill
Conversion Kit:
TG1003LP
ANS Z83.11
CSA 1.8 - 2016
Food Service Equip.
MH62943
Intended for other than houshold use - Non destine a l'usage domestique
2. Fill in the details required on the Installation Plate, supplied in the kit,
and affix to the rear of the griddle.
CONVERSION BY QUALIFIED SERVICE AGENCY
THIS APPLIANCE WAS CONVERTED ON:
day
month
to LPG gas with KIT #:
by: C ompany
Address:
Which accepts the responsibility that this conversion has been properly made
3. Affix the Warning Label, supplied in the kit, near the regulator.
LPG GPL
FOR LP GAS WHEN EQUIPPED WITH NO. 53 DRILL SIZE ORIFICE
POUR LP GAZ LORSQU' ÉQUIPÉ 'AVEC UNE OUVERTURE
DE TAILLE DE MÈCHE NO. 53
MAN.PRESS.
10.0
INCH W.C.
PRESS. MAN.
TOTAL INPUT
TOTAL D'ENTRÉE
56,000
BTU/HR
BTU/H
FOR USE IN NON COMBUSTIBLE LOCATIONS ONLY
DOIT ETRE UTILISE SEULEMENT DAS DES LOCAUX NON INFLAMMABLES
FOR YOUR SAFETY REFER TO INSTALLATION INSTRUCTIONS FOR CONVERSION PROCEDURES
®
Input:
000 BTU
Manifold Pressure : 10" WC
Max. Pressure : 14" WC
Made in China
Fabrique aux La China
Hecho en China
year
CLEARANCES
ESPACES LIBRES
BACK
6"
ARRIERE
RT SIDE
6"
COTE DROIT
LT SIDE
6"
COTE GAUCHE