Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Cayenne
Safety Precautions
To ensure safe operation, read the following statements and understand
their meaning. This manual contains safety precautions which are
explained below. Please read carefully.
WARNING
Warning is used to indicate the presence of a hazard that will or can
cause severe personal injury or death.
CAUTION
Caution is used to indicate the presence of a hazard that will or can
cause minor or major personal injury if the caution is ignored.
NOTICE: Notice is used to note information that is important but not
hazard-related.
WARNING
Fire, Injury, Death Hazard
This conversion kit shall be installed by a qualified service
agent in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority
having jurisdiction.
If the information in these instructions is not followed
exactly, a fire, an explosion, or the production of carbon
monoxide may result, causing property damage, personal
injury, and/or loss of life.
The qualified service agent is responsible for the proper
installation of this kit. The installation is not proper and
complete until the operation of the converted appliance is
checked as specified in the manufacturer's instructions
supplied with the kit.
®
Medium-Duty Flat Top Griddles – Conversion to LP Gas
©
2018 The Vollrath Company L.L.C.
Installation Instructions
Griddle
Item No. Model No. Description Kit Item No.
40718
FTG9012 12" Griddle XFTG1001LP
40719
FTG9016 18" Griddle XFTG1002LP
40720
FTG9024 24" Griddle XFTG1003LP
40721
FTG9036 36" Griddle XFTG1004LP
40839
FTG9048 48" Griddle XFTG1005LP
40840
FTG9060 60" Griddle XFTG1006LP
TOOLS YOU WILL NEED
• Wrenches: 8mm, 13mm and 22mm
• Flat head screw driver
• Jointing paste
• Flame source with 8" (20.3 cm) reach
• Soapy water for testing connections
Conversion Kit
Contents
Jet #53 Drill
Rating Plate
Installation Plate
Warning Label
Jet #53 Drill
Rating Plate
Installation Plate
Warning Label
Jet #53 Drill
Rating Plate
Installation Plate
Warning Label
Jet #53 Drill
Rating Plate
Installation Plate
Warning Label
Jet #53 Drill
Rating Plate
Installation Plate
Warning Label
Jet #53 Drill
Rating Plate
Installation Plate
Warning Label
Part No. 350674-1 ml
8/27/18
Qty.
1
1
1
1
1
1
1
1
2
1
1
1
3
1
1
1
4
1
1
1
5
1
1
1

Publicité

loading

Sommaire des Matières pour Vollrath Cayenne FTG9012

  • Page 5 été vérifiée, comme spécifié dans les • Source de flamme de 8"(20,3 cm) de portée instructions du fabricant fournies avec le kit. • Eau savonneuse pour tester les raccordements © 2018 The Vollrath Company L.L.C. Num. d’art. 350674-1 ml 8/27/18...
  • Page 6 CONVERSION Réglage du détendeur AVERTISSEMENT Procédez comme suit pour régler le détendeur de gaz pour un Risque de départ de feu, blessures ou danger de mort fonctionnement à 10" C.E. avec le gaz PL. Avant de commencer la conversion, vous devez couper 1.
  • Page 7 1. Apposez la plaque des valeurs nominales, fournie dans le kit, à côté de l'original, à l'arrière du gril.. Vérification de la pression de la ligne d'arrivée de gaz The Vollrath Company, LLC ® Sheboygan,WIUSA Avant de raccorder le gaz au détendeur, vérifiez la pression de la ligne 1-888-882-6845 d'arrivée de gaz.
  • Page 8 Produits à induction : 800.825.6036 Télécopieur : 800.752.5620 ou 920.459.6573 Réchauds de comptoir : 800.354.1970 Service clientèle : 800.628.0830 Tous les autres produits : 800.628.0832 www.vollrath.com Service clientèle Canada : 800.695.8560 © 2018 The Vollrath Company L.L.C. Num. d’art. 350674-1 ml 8/27/18...