Menu Level 2
Level 1
Online Un.Its N
Operate Mode
Sv1 State
Sv2 State
Sv3 State
Pump_I
Pump_O
Pump_C
Pump_S
Pump_D
Pipe Bckp He
Tank Bckp He
Gas Boiler
T1 Leav W Temp
Water Flow
Heat Pump Cap
T5 W. Tank
Tw2 Cir2 W. Temp.
T1S1 Cir1 Cli Temp
T1S2 Cir2 Cli Temp
Tw_O Plate Out Temp.
Tw_I Plate Inl Temp.
Tbt1 Buf Tank Up Temp.
Tbt12 Buf Tank Low T.
Tsolar
Operation
Idu Sw
Param.
Odu Model
Compr Current
Compr Freq
Compr Run Time
Compr Run Time Tot
Exp Valve Open
Fan Speed
Unit Target Freq.
Freq Lim Type
Supply Voltage
Dc Gener Voltage
Dc Gener Current
T2 Plate Gas Out T.
T2B Plate Gas In T.
Th Comp Suc Temp
Tp Comp Disch Temp
T3 Outd Exch Temp
T4 Outd Air Temp.
Tf Modul Temp
P1 Compr H_Press
P2 Compr L_Press
Odu Sw Date
Odu Sw Ver
Idu Sw Date
Idu Sw Ver
For servi-
Password
ceman
EN
112
Menu Level 3
Menu Level 4 Menu Level 5
on/off
Cod. 3541V941 - Rev. 05 - 06/2022
Description
Online Un.Its N
Operating mode (Heat or Cool or Off)
State of the 3-way valve SV1 (plant=off, DHW=on)
State of the 3-way valve SV2 (off=cool, on=heat)
State of the 3-way valve of zone 2 (mixing valve)
State of the water pump of the unit
State of the water pump of zone 1
State of the water pumpe zone 2
State of the solar water pump
State of the DHW recirculation pump
State of the backup heater IBH1
State of the DHW boiler el. heater TBH
State of the gas boiler
Water temperature measured by probe T1
Water flow rate (estimated)
Heat pump capacity (estimated)
Water temperature measured by probe T5
Water temperature measured by probe Tw2
Water setpoint calculated by climatic curve for zone 1
Water setpoint calculated by climatic curve for zone 2
Water temperature measured by probe Tw_out
Water temperature measured by probe Tw_in
Water temperature measured by probe Tbt1
not used
Water temperature measured by probe Tsolar
IDU Software
ODU model
Compressor input current
Compressor working frequency
Working time from the last start of the compressor
Total workin time of the compressor
Expansion valve opening steps
Fan speed
Unit target frequency
Frequency limiting scheme
Supply voltage
DC bus voltage
DC bus current
Water temperature measured by probe T2
Water temperature measured by probe T2B
Water temperature measured by probe Th
Water temperature measured by probe Tp
Water temperature measured by probe T3
Water temperature measured by probe T4
Water temperature measured by probe Tf
P1 high press compressor
P2 low press compressor
Outdoor unit SW date
Outdoor unit SW version
Indoor unit SW date
Indoor unit SW version
Password to access to service menù
OMNIA S 3.2
Unit of
Lower
Upper
Resolu-
Default
mea-
limit
limit
tion
value
sure
/
/
/
/
/
0
3
1
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
ON
OFF
/
/
/
/
/
1
°C
/
/
/
0,001
m3/h
/
/
/
0,1
kW
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
/
°C
/
/
/
1
°C
/
/
/
/
/
/
/
/
/
/
/
/
/
1
A
/
/
/
1
Hz
/
/
/
1
min
/
/
/
1
h
/
0
500
1
STEP
/
0
650
10
RPM
/
/
/
1
Hz
/
/
/
/
/
/
0
450
1
V
/
0
255
1
V
/
0
255
1
A
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
/
/
1
°C
/
0
5000
1
kPa
/
0
5000
1
kPa
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
9999
1
/
/