OMNIA S 3.2
Holiday mode (Holiday)
Menù Hp > Options > Holiday
This function is intended to prevent the house from freezing in winter when you are away from home for holidays and to reactivate the unit shortly before the end of
the holidays.
In holiday mode, the heating set point, the DHW set point, the management of the DHW valves / pumps and the system are managed independently by the hydronic
board.
Enabled Y/N
Dhw Mode On/Off
Disinfect On/Off
Heat Mode On/Off
From Date
Until Date
If DHW and Anti-legionella is enabled, the Anti-legionella function is temporarily disabled and an anti-legionella cycle will be performed at 11.00 pm on the last day of
vacation.
All timed functions are disabled.
The climatic curves are temporarily disabled and will automatically return to validity at the end of the holiday period.
The set point is not valid, but the value still appears on the main page.
Plant Backup Heater (Backup Heater)
Menù Hp > Options > Backup Heater
It allows (only in Heat mode) to force the activation of the electric system heater and make the heating of the water sent to the heating system more speedy.
Bckp Heat On/Off
8.7.4 Service information
Parameters (Parameters)
Menù Hp > Service information > Parameters
In this menu it is possible to consult the following parameters:
Main Set Temp
Main Actual Temp
Tank Set Temp
Tank Actual Temp T5
Smart Grid Run Time Info
Display
Menù Hp > Service information > Display
In this menu it is possible to set the time, date, language, backlighting, unit operating time with Smart Grid input active .
Date and time
Contrast
on/off
Brightness
Backlight time
Smart Grid Run
Smart Grid
Time
Error code (Error code)
Menù Hp > Service information > Error code
In this menu you can consult the chronological list of the last 10 alarms (the first in the list is the last one) complete with the date and time of the intervention.
Code
Error List
Date
hh.mm
8.7.5 Operation Parameter (Operation Parameter)
Menù Hp > Operation Parameter
It allows you to view all the operating parameters of the unit.
activates holiday mode
to set if DHW is on/off during the holidays
to set if the disinfect function is enabled/disabled during the holidays
to set if the heating mode is enabled/disabled during the holidays
first day of holiday
last day of holiday
Enabling and disabling of back-up electric heater (1=ON - 2=OFF)
system temp set point temp based on selected mode
Water delivery temperature (TW_OUT)
Setpoint DHW heater (T5s)
Temperature DHW heater (T5)
total daily run time of the smart grid
to set the date and time
to set the display contrast
to set the display brightness
to set the start of the backlighting
set working time for SMART GRID
error codes
date of the event
time of the event