Installation - External & In-Line Blower
Preparation
The following instructions are for preparing
the hood for use with an external or in-line
blowers models CBE-1000 or PBN-1000A.
CAUTION: To reduce the risk of fire and electric
shock, install this rangehood only with remote
blowers rated maximum 6.2 A.
For internal blower instructions please turn to
page 13.
1. Remove the (6) screws securing the blower pla-
te to the blower housing and remove blower
plate. See.Fig.1
2. Detach rectangular metal plate from blower pla-
te. See Fig. 2A Flip blower plate 90 degrees and
attach rectangular plate to blower plate side
with round knock-out.See Fig.2B
3. Re-install blower plate into blower housing by
following reverse instructions from step 1 then
use the screws provided to complete installa-
tion. (Tot.14)
4. Remove top knock-out plate and remote blower
knock-out plate by using a flat head screwdriver.
See Fig. 3 and Fig. 4
5. Secure 8" round blower collar to top of blower
- 15 -