PROBLEM
No or low
6.
pressure
(initial use)
(continued)
7.
8.
9.
Will not draw
1.
cleaning solution
2.
3.
4.
5.
6.
7.
8.
D30333
All manuals and user guides at all-guides.com
CAUSE
Air in hose.
Choke lever in the
"Choke" position.
Throttle control lever is
not in the "Fast" position.
High pressure hose is too
long.
Wand not in low
pressure.
Filter clogged on
chemical injector rinsing
hose.
Screen on end of
chemical injector rinsing
hose not in water
Chemical too thick
Pressure hose is too long
Chemical build up in
chemical injector.
Hoses are not
connected.
Control valve is in the
down (off) position or
pointed toward the tank
not being uses.
22- ENG
CORRECTION
6.
Turn off the engine, then the
water source. Disconnect
the water source from the
pump inlet and turn the
water source on to remove
all air from the hose. When
there is a steady stream of
water present, turn water
source off. Reconnect water
source to pump inlet and
turn on water source.
Squeeze trigger to remove
remaining air.
7.
Move choke to the "No
Choke" position.
8.
Move throttle control lever to
the "Fast" position.
9.
Use high pressure hose
under 100 feet.
1.
See Spray Wand paragraph
in the Maintenance section
for the correct procedure.
2.
Clean filter.
3.
Make sure end of chemical
injector rinsing hose is fully
submerged into clean water.
4.
Dilute chemical. Chemical
should be the same
consistency as water.
5.
Lengthen water supply hose
instead of high pressure
hose.
6.
Have parts cleaned or
replaced by AWSC.
7.
Make sure all hoses are
connected at valve.
8.
Turn control valve toward
tank being used.