5-29
5-30
Note:
We suggest you keep the wheel in position with the
brake pedal until the selection has been made.
— Use the F5 menu key to select the Hidden Weight
behind spokes item.
The function is now selected and on the right of the
screen two balancing gauges are shown instead of
one (Fig. 5-29).
— Proceed, if necessary, with Optimization/Minimization
F
(
5.10), or apply the compensation weights directly.
To exit the Hidden Weight mode and display the normal
indication of imbalances (Fig. 5-30) proceed in the
same way.
As long as an Alu 2, Alu 2P, Alu 3 or Alu 3P are set,
weight placement behind the spokes can be activated
at any time.
Exiting the BALANCING screen does NOT exit the
Hidden Weight function.
Note:
The unbalance reading is only subdivided on two
fi tting positions when the spoke position is stored.
When balancing with counterweights positioned
behind the spokes if you also need to perform an
Optimization/Minimization run, do it before applying
the weights.
After running an Optimization/Minimization procedure
by selecting the weights positioned behind
the spokes mode, the imbalance indicated is
automatically split into two application points behind
the spokes.
EEWB334A
35