Open the gate leaf (the grub screws on the mechanical stops are loose) and fi t the pin
Fasten using the UNI6593 washer Ø 10 and the supplied UNI 5739 M10 X 10 bolt b
Establishing the limit-switch points
Before establishing the endstop points, you need to: release the gearmotor (see paragraph on manually releasing
it) and remove covers 1 and 2 while carefully following the illustrations.
⚠ DO NOT REMOVE cover 1 without fi rst sliding it.
❷
⚠
❶
into the gate bracket.
.