Laying the corrugated tubes
Set up the junction boxes and corrugated tubes you will
need to make connections coming from the junction
pit. To connect the gearmotor we suggest a Ø 60 mm
corrugated tube. Whereas for the accessories we
suggest Ø 25 mm tubes.
The number of tubes depends on the type of
system and the accessories you are going
to fit.
Fastening the brackets
Establish the gate bracket fastening point and find the bracket's fastening point to the post, while respecting the
quotas shown in the drawings and tables.
Opening (°)
90
115
⚠ The greater the gate leaf's opening angle, the greater the opening speed and the slower is the gearmotor's thrust.
The smaller the gate leaf's opening angle, the slower the opening speed and the greater is the gearmotor's thrust.
A (mm)
B (mm)
130
110 ÷ 170
150
110 ÷ 160
C (mm)
E (mm)
0 ÷ 60
750
0 ÷ 50
750
≤60
E