4. Timer function
Automatic start: the air conditioning unit is off. Press on Timer and se-
lect the desired temperature using Temp+(Up)/Temp-(Down). If the dis-
play shows 4, for example, the air conditioning unit will start in 4 hours.
Automatic stop: the air conditioning unit is on. Press on Timer and
select the desired temperature using Temp+(Up)/Temp-(Down). If the
display shows 8, for example, the air conditioning unit will switch off in
8 hours.
The timer can be set to between 1 to 24 hours.
5. Night function
Press on Mode until the Cool light shows on the display.
Set the desired temperature.
Press the 'Sleep' button; after 1 hour, the temperature will increase by
1°C and after 2 hours, by 2°C.
The unit will continue to work on this setting.
Water outlet
During the cooling process, the device removes water from the air. This
largely evaporates but any excess water is collected in the water reservoir.
If the water reservoir in the device is full, the compressor and the motor will
stop automatically and the 'water tank full' light (W.F.) will come on. In this
event, switch the air conditioning unit off and remove the plug from the
socket. Empty the water tank by removing the cap from the water drainage
point (see picture) and draining the tank into a drain or receptacle. Do not
forget to replace the cap again afterwards! You can then switch the air con-
ditioning unit back on.
When dehumidifying, more water is removed from the air. This is why you
must connect a hose to the water drainage hose during dehumidifying and
run this to a drain (at a lower point).