* Drain lines should not be piped directly to the
sewer system. A vertical air gap of a minimum of 5
cm should be between the end of the drain pipes
from the icemaker and the storage bin and the
floor drain.
Water Supply
Inlet G3/4
Water Supply Line
Shut-off Valve
Drain Valve
Separate piping to approved
drain. Leave a 5cm vertical
air gap between the end of
each pipe and the drain.
Floor
Fig. 6
6. START-UP PROCEDURE
1) Check that the power supply cord is disconnected.
2) Move the Operation Switch on the Operation
Panel to the "ON" position.
Ice Button
Display
ICE
DRAIN
STOP
MODE
ICE
STOP RESET
Once STOP Button is pushed,
ICE Button cannot start ice
production for 20 min.
Operation Panel
Fig. 7
All manuals and user guides at all-guides.com
Drain Outlet
R3/4
Bin Drain Outlet
3/4 FPT
5cm air gap
Drain
Stop Button
Reset Button
Operation Switch
3) Open the water supply tap.
4) Connect the power supply and energise.
5) The Display will illuminate in the "ICE" mode.
6) The following should occur in sequence:
a) Water Reservoir will fill.
b) Gear Motor will start.
c) Compressor will start.
IMPORTANT
1. Check the conditions and quality of the ice
production.
2. Do not use ice produced in the trial run. It
might be contaminated with foreign matter in
the water circuit. Discard or flush down the
drain.
3. Clean the Storage Bin before use (see "III. 1.
CLEANING" in Instruction Manual).
7. FINAL CHECKS
1) Is installation free of water leaks?
2) Is the icemaker free from vibration?
3) Are all the panels fixed and secure?
4) Has the user been instructed on correct machine
use and handed the Instruction Manual?
4