Télécharger Imprimer la page

Hypertherm Powermax 1000 Bulletin Technique page 2

Remplacement du pa igbt
Masquer les pouces Voir aussi pour Powermax 1000:

Publicité

Les langues disponibles

Les langues disponibles

Introduction
Purpose
Describes the necessary steps to replace the PA IGBT in the Powermax1000, 1250, and 1650.
Tools and materials needed
#2 Phillips screwdrivers
Kit contents
Kit 128699 (PMX1000)
Part number
Description
075567
Machine Screws M6 X 16-12.5
075570
Machine Screws M5 X 14-12
109239
PA IGBT: 1200V 50A
123604
PA IGBT Gate-drive wire
128836
Grease
Kit 128674 (PMX1250)
Part number
Description
075567
Machine Screws M6 X 16-12.5
075570
Machine Screws M5 X 14-12
109238
PA IGBT: 1200V 75A
123604
PA IGBT Gate-drive wire
128836
Grease
Kit 128748 (PMX1650)
Part number
Description
075567
Machine Screws M6 X 16-12.5
075570
Machine Screws M5 X 14-12
109319
PA IGBT: 1200V 145A
123604
PA IGBT Gate-drive wire
128836
Grease
Field Service Bulletin
All manuals and user guides at all-guides.com
POWERMAX1000/1250/1650 PA IGBT REPLACEMENT
Disconnect electrical power before performing any maintenance.
See Section 1 of the Operator Manual for more safety precautions.
WARNING
ELECTRIC SHOCK CAN KILL
Qty
2
2
1
1
1
Qty
2
2
1
1
1
Qty
2
2
1
1
1
1

Publicité

loading

Ce manuel est également adapté pour:

Powermax 1250Powermax 1650