► Do not extract hot materials.
► Do not extract liquids.
► If the dust extractor is employed to extract hazardous materials, appropriate personal protective
gear must be worn and steps must be taken to ensure that the exhaust air is properly ventilated.
Please refer to the associated safety data sheets for specific requirements.
► Dispose of extracted material according to local statutory regulations.
Authorized Persons
Operation and maintenance of the device may only be performed by qualified personnel.
Product Description
Components and Functional Elements
See Fig. 1 (on inside cover)
1 SILENT compact
2 Key-pad
3 Dust drawer
4 Fine filter
5 Mains cable
6 Suction hose
7 Exhaust air filter / exhaust air outlet
See Fig. 2 (on inside cover)
20 Display automatic operation
21 Operating mode key, automatic,
continuous operation
22 Display continuous operation
Setting Up
Setup
The extraction unit is a free standing appliance which must not be operated in a lying position.
If the device is to be installed in a cabinet, an opening for the exhaust air with the following dimensions
must be provided, in addition to the openings for the suction hoses:
• Circular opening:
• Rectangular opening:
Connection
⇒ Insert the suction tube (6) into the suction port (8).
⇒ Connect the suction tube to the relevant suction point.
⇒ If necessary, shorten the suction tube.
Caution, risk of injury!
When shortening the suction tube, please ensure that the integrated wire is cut as straight as
possible.
If the diameter size does not correspond, please use an adapter to prevent a loss in suction per-
formance.
Long suction hoses, tight bends and kinks will considerably reduce the extraction force at the
extraction point.
⇒ Connect the electronic device to the power socket (12) at the back.
When connecting an electronic device to the extraction unit, please ensure that the maximum
permissible capacity for connected devices is not exceeded (Technical data).
⇒ Switch the device OFF at the On / Off switch (9).
⇒ Connect the power cable (5) to the power supply (10).
⇒ Insert the power plug into the building installed wall socket.
Min. 120 mm diameters.
Min. 170 x 65 mm.
- 3 -
8 Suction port
9 On / Off switch
10 Power supply
11 Device protection switch
12 Unit power socket
13 Service flap
23 Suction level key
24 Display empty suction drawer
25 Enter key, save input
26 Display error message
EN