Antari M-5 & M-10 on-board DMX settings
Channel A
6-255
Volume Control
(5% - 100%; 255 is the
maximum output)
0-5 OFF
The fog machines M-5 & M-10 have on-board DMX control. They use 2
channels to control volume output operation. Channel A has a value range of
0 to 255 and Channel B has a range of 251 to 255. Timer functions such as
duration and interval can be programmed via the DMX controller or the DMX
control software used by the lighting and effects operator.
Channel A (Volume Control)
If Channel A has a value from 0 to 5, the unit is OFF.
Between the values 6 to 255, the output will be linear. With 6 being the
minimum volume of fog produced and 255 approaching the maximum. The
volume output rises as the DMX value is increased.
Channel B (Nonstop Burst)
If Channel B has a value from 251 to 255, the machine will operate with
Nonstop Burst (Continuous fogging). In this mode, the unit automatically
adjusts itself and produces a large amount of fog. It requires no reheating
period and produces fog continuously.
Function Priority
When Channel A is set to a value between 6 to 255 and Channel B is set
between 251 to 255 at the same time, Channel B will override Channel A and
the unit is in Nonstop Burst mode.
Addressing Example
If the unit is assigned to DMX address 124 e.g., Channel A corresponds to
DMX address 124 and DMX address 125 will automatically be selected for
Channel B.
The Antari fog machines M-5 & M-10 with on-board DMX conform to the
following performance specifications:
1.Average Operating temperature=250°C
2.Continuous fog output is available by selecting "Nonstop Burst" under the
Function sub-menu "Volume Out" or by setting the DMX address between
251-255 in channel B.
Channel B
251-255
Nonstop Burst
0-250 OFF