8. Troubleshooting and maintenance

No laser line
Check that the batteries are inserted correctly in the transmitter unit.
Replace the batteries.
Ensure that the laser window in the transmitter unit is not obstructed
by dirt. If necessary, clean with cotton cloth.
Lost calibration
If the tool loses its calibration, return the complete tool to SKF for repair.
Heavy impacts
The transmitter unit is equipped with sensitive optical components. Heavy
impacts can affect the function and accuracy of the unit. Handle with care and
ensure that the laser window is kept clean and free from dirt.

9. Technical data

Designation
Transmitter Unit
Type of laser
Laser line
length
Measurement
Accuracy
Angular
Measurement
Accuracy Offset
Measurement
distance
Control
Housing
Material
Transmitter
unit
dimensions
Transmitter
unit weight
Receiver Unit
Housing
Material
SKF TKBA 10 & 20
TKBA 10
Red laser diode
2 m at 2 m
(6.6 ft at 6.6 ft)
Better than 0,02°
at 2 m (6.6 ft)
Better than 0,5 mm
(1/50" in.)
50 mm to 3 m
(2 in to 10 ft)
Laser ON/OFF rocker switch Laser ON/OFF rocker switch
Aluminum,
Powder coat finish
169 × 51 × 37 mm
(6.65 × 2.0 × 1.5 in.)
365 g
(0.8 lbs)
Aluminum,
Powder coat finish
TKBA 20
Green laser diode
2 m at 2 m
(6.6 ft at 6.6 ft)
Better than 0,02°
at 2 m (6.6 ft)
Better than 0,5 mm
(1/50" in.)
50 mm to 6 m
(2 in to 20 ft)
Aluminum,
Powder coat finish
169 × 51 × 37 mm
(6.65 × 2.0 × 1.5 in.)
365 g
(0.8 lbs)
Aluminum,
Powder coat finish
13