6. Alignment Condition check
The laser line on the reflector unit shows the vertical angle misalignment and
parallel misalignment or offset. Horizontal angle misalignment is indicated by
the position of the reflected laser line on the transmitter unit.
Before aligning the pulleys it is important that the pulleys are mounted
correctly on the shafts and that the shafts are straight. Buckled pulleys will
have a detrimental effect on the alignment quality.
7. Correcting misalignment
Vertical
Parallel
Horizontal
angle
angle
Figure 5 Misalignment summary
10
SKF TKBA 10 & 20