Télécharger Imprimer la page

Dometic DrawBar5S Notice D'utilisation page 20

Masquer les pouces Voir aussi pour DrawBar5S:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
Using the presentation mode
With presentation mode activated the interior LED
lamp stays on permanently.
➤To activate and deactivate the presentation
mode, press simultaneously the
button for at least 2 seconds (fig. g,
the
page 11).
✔ All temperature indicator LEDs flash for 1 time.
Using the demo mode
With demo mode activated the compressor and
fans are switched off.
➤To activate the demo mode, press the
button for at least 6 seconds (fig. h,
page 11).
✔ All temperature indicator LEDs flash for 3 times.
Troubleshooting
Fault
The device does not cool. Tempera-
ture indicator LEDs do not glow.
The device does not cool (plug is
inserted). Temperature indicator
LEDs glow.
The device does not cool (plug is
inserted). Temperature indicator
LEDs for 11 °C and 14 °C light up
permanently.
The interior LED lamp stays on per-
manently even when the wine cool-
ing drawer is closed.
The device does not cool sufficiently.
Temperature indicator LEDs glow.
The upper temperature indicator LED
flashes repeatedly for 1 time.
The upper temperature indicator LED
flashes repeatedly for 3 times.
The upper temperature indicator LED
flashes repeatedly for 4 times.
20
✔ The temperature indicator LEDs for 11 °C and
14 °C light up permanently.
➤To demonstrate the temperature setting func-
tion or the presentation mode, press the
button and
✔ The temperature indicator LEDs for 11 °C and
14 °C turn off within 2 seconds.
✔ The temperature indicator LED of the last
selected temperature level lights up.
➤To deactivate the demo mode, press the
page 11).
✔ All temperature indicator LEDs flash for 3 times.
✔ The temperature indicator LED of the last
selected temperature level lights up.
Possible cause
No voltage present in the AC volt-
age socket.
The cooling element is defective.
The demo mode is activated.
The presentation mode is activated. Switch off the presentation mode
The cooling element is defective.
The ventilation is insufficient.
The temperature sensor is defective. Contact authorized service agent for
The inner fan is defective.
The outer fan is defective.
4445103438
button once.
button for at least 6 seconds (fig. h,
Suggested remedy
Try using another plug socket.
Contact authorized service agent for
repair.
Switch off the demo mode (fig. h,
page 11).
(fig. g, page 11).
Contact authorized service agent for
repair.
Remove any obstruction or soiling
from the inlet and outlet vents.
repair.
Contact authorized service agent for
repair.
Contact authorized service agent for
repair.
EN

Publicité

loading

Ce manuel est également adapté pour:

Drawbar5bDrawbar5c