3.3 The flow bar

The flow bar is a graphical representation of the water volume through the unit. The heat pumps has
it best performance when the flow bar is in the green zone. The graph is only valid after at least 30
minutes of operation. The flow bar also represents the three-minute time delay before the actual start
of the unit. The indication "flow" is not visible; the small block at the very right end of the flow bar is
flickering and disappears after a while. When they are all gone, the unit will start.

4. Maintenance and inspection

4.1 Maintenance

Check the water supply to the unit often. Low water flow and air entering into the system
should be avoided, as this will diminish the units' performance and reliability. You should
clean the pool/spa filter regularly to avoid damage to the unit as a result of the dirty or
clogged filter.
The area around the unit should be dry, clean and well ventilated. Clean the side
heating exchanger regularly to maintain good heat exchange and to save energy.
Check the power supply and cable connection often. Should the unit begin to operate
abnormally or do you smell something unusual around the electrical compartment,
switch off the heat pump and have it replaced on a timely manner.

4.2 Trouble shooting guide

Improper installation will create an electrical hazard, which could result in death or serious injury to
pool users, installers, or others due to electrical shock, and may also cause damage to property.
Attention:
DO NOT attempt any internal adjustments inside the heater.
Attention:
Keep your hands and hair clear of the fan blades to avoid injury.
Attention:
If you are not familiar with the pool filtering system and heater:
• Do not attempt to adjust or service without consulting your dealer,
• Read the entire installation and users guide before attempting to use,
• Do not start the heat pump until 24 hours after installation to
Attention:
Turn off power to the unit prior to attempt service or repair.
Problem
Heat pump not running
Insufficient heating
4.3 Error messages
The heat pump will show an error message in case of a problem. The following messages can
occur:
Error message
Low air temp
18
professional pool or air conditioning contractor.
service or adjust the heater or pool filtering system.
avoid damaging the compressor.
1. No electricity
2. Unit not turned on
3. Wrong temperature settingr
4. Time delay still activated
5. Air temperature below 8°C
6. Other
1. Obstacles blocking air flow
2. Ice on the evaporator
The heat pump will not start when
the ambient air temperature is
below 8°C.
Cause
Oorzaak
Solution
1. Switch on the electrical power
2. Switch on the heat pump
3. Adjust the temperature setting
4. Wait 3 min for unit to start
5. Wait until temperature has
risen
6. See further under 'error mes-
sages'
1. Remove obstacles
2. Turn of the unit (air too cold)
Oplossing
the unit will start as soon as the
ambient temperature reaches
8°C.