Changing the clamping jaw.
The clamping jaws are wearing parts. If you are unable to rivet in a single working
stroke you should change the clamping jaws:
I.
(1) Nose casing
II.
(2) Jaw's housing
(3)
Riveting machine
(4)
Clamping jaws (3 parts)
Remove the nose casing (1) and the Jaw's housing (2) from the device (3) and remove
the clamping jaws (4) from the Jaw's housing (2).
III.
Hold the Jaw's housing (2) so that its forward part is faced down.
Place the clamping jaws (4) in the Jaw's housing (2) with their smooth sides facing
outwards.
IV.
Mount the Jaw's housing (2) with the new clamping jaws (4) and finally replace
the nose casing (1).