Withdrawing from operation

f Unscrew the nose piece screw
f Remove the nose piece
f Carefully remove the blade
f Insert a new undamaged blade of the same size and design (see section "Spare parts and
accessories"). In doing so, pay attention to the correct direction of installation
slanted side of the blade must be aligned towards the application tool.
f Replace the nose piece.
f Tighten the screw for the blade holder.
10 Withdrawing from operation
When used for its intended purpose, the application tool will perform continuously without issues.
Should the application tool need to be withdrawn from operation, it must be disposed of correctly
in accordance with the country-specific disposal guidelines.

11 Spare parts and accessories

NOTE
The use of spare parts and accessories not approved by the manufacturer may lead to damage of the
application tool.
f Use only approved spare parts and accessories otherwise warranty claims shall be rendered void.
Spare parts and accessories can be procured direct from the respective HellermannTyton country
representative.
Spare parts/accessories
Spare blade MK7P
Nose piece
Locking disc
Nose piece screw
Adjustment lock cap
Pneumatic hose

12 Technical data

Dimensions
TYPE
(W x H x D)
MK7P
220 x 170 x 40 mm
= Tension force
8
(Figure
) with a screwdriver.
1
C
.
3
.
2
Max . strap
width
Weight
4.8 mm
0.43 kg
Operating Instructions • MK7P • 09-2016• 031-93401
Article-No .
110-07111
110-10213
110-07545
110-10130
110-07200
110-30002
Approx. 60 to 170 N (adjustable)