Festo HGPPI Serie Mode D'emploi page 27

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
Flashing
Description
sequence
On (2 s)
Booting
Off
Normal operating
status, no malfunction
active
1x
Undervoltage in load
supply
2x
Execution error at
function call
3x
PROFIBUS: Impermis
sible address
4x
PROFIBUS: Faulty
parameter data
5x
PROFIBUS: Imper
missible configuration
data
6x
Hardware fault
7x, 8x, 9x
Reserved
10x
Internal error, firmware
error
Festo HGPPI−... 0605NH English
Elimination
Check/reapply the power
supply. Acknowledge mal
function with function 1 (reset)
Correct error in PLC/IPC;
Acknowledge malfunction with
function 1 (reset)
Switch off, correct address on
the DIL switches and switch on
again
Correct the parameter data in
the master and re−establish
PROFIBUS communication
Correct the configuration data
in the master and re−establish
PROFIBUS communication
Exchange module/HGPPI
Servicing required
27

Publicité

Table des Matières
loading

Table des Matières